When using the 1st generation Zip Fix Application Instrument it is possible to cut the implant while the tensioning trigger is being squeezed which could lead to loosening of the implant.

Aug 13, 2013 Surgical Instruments Nationwide View Details →

PENTAX Medical has become aware of a product issue associated with the OF-B194 Gas/Water Feeding Valve. A manufacturing defect may cause improper stoppage of CO2 gas during an endoscopic procedure with the potential for serious hazard to and/or user.

Sep 16, 2013 Infusion Pumps Nationwide View Details →

Medtronic notified customers regarding over stimulation or stimulation in the wrong area related to select Medtronic neurostimulators. Upon a specific set of conditions, typically related to device recovery from an over discharge, there is a potential for over stimulation or stimulation directed to a lead electrode other than what was intended.

Sep 30, 2013 Implants & Prosthetics Nationwide View Details →

The data printed on the thermal printer may omit a digit or decimal point in the results or sample identification number.

May 15, 2013 Diagnostic Equipment Nationwide View Details →

RAPIDPoint¿ 400 Series, RAPIDPoint¿ 500, or RAPIDLab¿ 1200 Series blood gas analyzer, users can inadvertently enter a wrong patient ID on the demographics screen, which ultimately could lead to a misidentification of the sample

Sep 17, 2012 Diagnostic Equipment Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

The firm initiated this recall of certain Toshiba Diagnostic Ultrasound Systems because it has been found that under certain conditions, the temperature of the transducer head may increase in 2D+PW mode or 2D+CDI (POWER, ADF) +PW mode. When the system is used under both conditions listed below, the temperature of the transducer head connected to the system may increase in temperature and possibly

Aug 5, 2013 Diagnostic Equipment Nationwide View Details →

The firm is issuing a voluntary recall due to the potential for pinholes in the packaging. Pinholes are a breach in the sterile barrier and could lead to potential contamination.

Sep 4, 2013 Infusion Pumps View Details →

During an audit, Carestream discovered a DRX-1 System that captured an image which displayed an artifact. This issue was discovered in manufacturing. It occurs when the DRX product console software is updated to v5.6b software and the detector is not calibrated before use.

Jul 26, 2013 Other Medical Devices Nationwide View Details →

HemoCue AB has become aware of a production related problem involving punctured HemoCue¿ Urine Albumin Microcuvettes single pack pouches.

Jul 16, 2013 Diagnostic Equipment Nationwide View Details →

Brand: The ForeCYTE Breast Health Test, Mammary Aspiration Specimen Cytology Test (MASCT), MASCT System Kits, Clarity System Kits, MASCT Patient Sample Kits & Clarity Patient Sample Kits Instrument, Biopsy. The MASCT System Kit, Patient Sample Kits, or the Nipple Aspirate Fluid Laboratory Kit has the following codes: PRODUCT CODE: AG-MASCT; AG-FC5; DTG-MASCT, DTG-FC5, and NRLBH-5. PART NUMBER: 9002513; 9002513MD; 9002528; 9002528MD; 9002587; 9002614; and 9002717MD. THE MASCT SYSTEM KIT CONSISTS OF: 1. MASCT Breast Pump; 2. Instructions for Use (IFU); 3. Heating Pad; 4. Timer; 5. Saccomono's Fixative; 6. Nu Prep Gel; 7. Welcome and Training Materials Coversheet; 8. MASCT System Order Form; 9. ForeCYTE Training Video DVD; 10. MASCT System Instructions with pictures - pink; THE PATIENT SAMPLE KIT CONSISTS OF: 1. Two (2) flower assemblies (e.g., filter, filter retainer, and filter holder); 2. Instructions for Use (IFU); 3. Two (2) specimen collection devices; 4. Two (2) breast bags for transporting the specimen collection container; 5. Barcode labels; 6. Saccomono's Fixative; 7. Nu Prep Gel; 8. MASCT System package insert; 9. ForeCYTE Test Requisition Form; 10. Patient Information Sheet; 11. Atossa Patient Information; 12. FED EX Clinical PAK; 13. MASCT System Order Form; 14. FED EX Pouch; 15. FED EX Airbill; Product Usage: The MASCT Device is intended for use in the collection of nipple aspirate fluid for cytological testing. The collected fluid can be used in the determination and/or differentiation of normal versus premalignant versus malignant cells.

Atossa Genetics

🏥 Medical Devices Class I - Dangerous

Atossa Genetics is recalling ForeCYTE Breast Health Test, Mammary Aspiration Specimen Cytology Test (MASCT) due to concerns raised by the U.S. Food and Drug Administration (FDA) in a warning letter received by Atossa in February 2013. The FDA raised concerns about (1) the current Instructions for Use (IFU); (2) certain promotional claims used to market these devices; and (3) the need for FDA cl

Sep 19, 2013 Diagnostic Equipment Nationwide View Details →

The sterility of this product to a Sterility Assurance Level (SAL) of 10(-6) cannot be assured.

Aug 28, 2013 Other Medical Devices Nationwide View Details →

Xoran MiniCAT CT Scanner

Xoran Technologies

🏥 Medical Devices Class I - Dangerous

A description of the defect in the product or the manner in which the product fails to comply wvith an applicable Federal standard; The MiniCAT CT Scanners subject to this notification failed to meet Xoran's specifications for dose rate of 125 ¿ 3 kVp. These 18 complaints received include dose rates both on the high and low end of Xoran's specifications. See ATTACHMENT 1 for details. (e) A n evalu

Jul 27, 2010 Diagnostic Equipment Nationwide View Details →

GE has recently become aware of potential issues due to out of context issues associated with specific workflows of the Centricity PACS RA1000 workstation. These issues are as follows: 1) In Centricity RIS-IC, and a RIS-Driven integration, the "close" button closes the exam in RIS-IC, but does not close the exam in Centricity PACS RA1000 Workstation. 2) Interrupted workflow could break the

Jun 11, 2013 Diagnostic Equipment Nationwide View Details →