All Recalls

95,089 total recalls in our database

🏥 Medical Devices Class I - Dangerous

Complaints that the tip of the awl broke after impaction during surgery.

Nov 22, 2016 Other Medical Devices View Details →

Product Defect; These products may produce a straight stream instead of a fully atomized plume of medication.

Oct 27, 2016 Infusion Pumps Nationwide View Details →

The rods are packaged in packages with unacceptable seals. In some cases, the integrity of the seal is compromised by channels or voids.

Nov 22, 2016 Surgical Instruments Nationwide View Details →

Stryker Instruments is voluntarily recalling specific lots of sterile MIS Toolsteel Burs because the burs may exhibit signs of corrosion.

Nov 30, 2016 Surgical Instruments Nationwide View Details →

Defective tips have the potential to pipette/dispense volumes 50-100% lower than is specified for the tips.

Oct 13, 2016 Other Medical Devices View Details →
🏥 Medical Devices Class I - Dangerous

AbbVie is issuing an urgent field correction notification due to an increased number of reports of disconnections of the AbbVie 20FR PEG tube from the Y-connectors.

Nov 22, 2016 Other Medical Devices View Details →

Greatbatch Medical the manufacturer of the 4F and 5F sheath/dilator components has determined that the products listed in their September 7, 2016 Recall Notification have the potential for the rotating luer to detach from the dilator hub during use. AngioDynamics has confirmed that affected sheath/dilators (Greatbatch Model Numbers 10904-001 and 10904-002) have been included in packaged AngioDynamics Stiffened Micro-Introducer Kits.

Sep 28, 2016 Surgical Instruments Nationwide View Details →

Product Defect; These products may produce a straight stream instead of a fully atomized plume of medication.

Oct 27, 2016 Infusion Pumps Nationwide View Details →

Owens & Minor is the initial importer and private label distributor of Medi Choice Arm Slings (Product). The Product is manufactured in China by Tops Medical Articles Nantong Inc. Owens & Minor first learned of the product issue that prompted the product removal action via customer complaints received in September 2016. Two customer complaints received on September 1"1, 2016 reported surface contamination on the arm slings. Two additional complaints reported on September 19, 2016 and October 7, 2016 reported the same issue. Upon receipt of the complaints on September 1, 2016, Owens & Minor immediately initiated a CAPA investigation for root cause analysis and determination of corrective/preventive actions. A quality inspection of inventory confirmed that the surface contamination was confined to lots manufactured in May, June, and July of 2016. The surface contamination for these lots was found to be frequent. Subsequent August product lots were inspected and no surface contamination was found. Limited inventory from lots prior to May 2016 were available and inspected as well. No surface contamination was found on these prior lots. Owens & Minor has quarantined the affected product lots. The product is on hold at all Owens & Minor Distribution Centers (DC). Samples of contaminated product have been sent to the manufacturer for evaluation and to a certified testing lab for identification of contaminate. These results are pending at this time. Based on the frequency of the product defect as well as evaluation of potential adverse health event risk, Owens & Minor initiated a voluntary recall for the above stated affected product lots.

Oct 31, 2016 Infusion Pumps Nationwide View Details →