Outer Packaging is not sterile

Nov 29, 2016 Infusion Pumps Nationwide View Details →

Software error. Potential for incorrect results

Oct 6, 2016 Diagnostic Equipment Nationwide View Details →

Outer Packaging is not sterile

Nov 29, 2016 Infusion Pumps Nationwide View Details →

Tina-quant Cardiac C-reactive Protein (Latex) High Sensitive (CRPHS) lot number 604450 (catalog number 11972855216) shows an under-recovery of up to -25% at concentrations below 5 mg/L on the MODULAR ANALYTICS P module. this issue can lead to erroneous low CRPHS results. CRPHS is used as a marker for the prediction of cardiovascular risk. An erroneous low result could lead to an incorrect cardiovascular risk assessment and subsequent delay of further examination.

Feb 26, 2016 Diagnostic Equipment Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

GE Healthcare Surgery announces a voluntary field action for the OEC 9800 and OEC 9900 Elite due to additional supplementation to the user documentation to include areas for enhanced planned maintenance and component replacement frequencies.

Dec 27, 2016 Other Medical Devices View Details →

Mallinckrodt discovered that some devices may have been manufactured with an out-of-tolerance manometer which can result in in an inaccurate proportional valve calibration table in an affected device.

Nov 21, 2016 Diagnostic Equipment View Details →

The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame a physical barrier (the tabletop support arm. height ca. 60 em) to access a prohibited area not intended as a working position. 2) The directions for use (device labeling and instructions for use) did not contain an explicit exclusion of the prohibited area. 3.) The movement was activated inadvertently and continuously. and it was not released (the movement requires continuous activation). 4.) Delayed activation of the emergency stop.

Feb 19, 2016 Other Medical Devices Nationwide View Details →

Customer complaints identified that samples containing extremely high IgG4 levels exhibit antigen excess and will yield spuriously low IgG4 results.

Sep 11, 2014 Other Medical Devices View Details →

Customer complaints identified that samples containing extremely high IgG4 levels exhibit antigen excess and will yield spuriously low IgG4 results.

Sep 11, 2014 Other Medical Devices View Details →

Customer complaints identified that samples containing extremely high IgG4 levels exhibit antigen excess and will yield spuriously low IgG4 results.

Sep 11, 2014 Other Medical Devices View Details →

Hitachi Oasis MRI System - C-Spine Coil

Hitachi Medical Systems America

🏥 Medical Devices Class I - Dangerous

The customer indicated that the coil balun was hot to the touch when removing the coil from the patient table after an exam.

Jan 6, 2017 Other Medical Devices Nationwide View Details →

Due to a production error, screws were not tightened to specified torque. These screws may come loose from the C-arm shaft causing the C-arm to rotate uncontrolled.

Dec 1, 2016 Implants & Prosthetics View Details →

The analysis showed that the incident was caused by a chain of four faults: 1.) The injured person overcame a physical barrier (the tabletop support arm. height ca. 60 em) to access a prohibited area not intended as a working position. 2) The directions for use (device labeling and instructions for use) did not contain an explicit exclusion of the prohibited area. 3.) The movement was activated inadvertently and continuously. and it was not released (the movement requires continuous activation). 4.) Delayed activation of the emergency stop.

Feb 19, 2016 Other Medical Devices Nationwide View Details →