The implant size is incorrectly etched on the implant. The size listed on the box is correct.

Jan 18, 2018 Infusion Pumps View Details →

Users manuals not supplied with 4800-00T US Rapid Therapy System

Sep 28, 2017 Infusion Pumps Nationwide View Details →

Possible blood leaks through the hydrophobic portion of the Pall LG6NS LeukoGuard Leukocyte Reduction Arterial Blood Filters.

Dec 18, 2017 Other Medical Devices View Details →

Following the completion of sterilization cycle(s) of the impacted Hex Driver, the epoxy color band on the impacted Hex Driver can migrate down the shaft and/or potentially onto the sterilization tray or caddy.

Jan 11, 2018 Infusion Pumps View Details →
🏥 Medical Devices Class I - Dangerous

Firm is recalling first aid/emergency kits and cabinets which contain Honeywell Eyewash (3 lots) which is being recalled due to leaking bottles.

Mar 20, 2018 Other Medical Devices Nationwide View Details →

Product has been found with a missing Washer, Retaining Ring, and/or Stop Screw. Recalling firm was notified by distributor that Refractor Suspension Arm fell on a patient s lower torso along with the arm housing

Dec 6, 2017 Diagnostic Equipment Nationwide View Details →

Certain lots of M-30D diluent used with BC-3200 and BC-3600 Hematology Analyzers and M-53D diluent used with BC-5390 Hematology Analyzer may cause the system to produce an elevated platelet background count.

Jan 24, 2018 Other Medical Devices View Details →

The infusion sets were manufactured with an incorrect spin collar.

Feb 5, 2018 Surgical Instruments Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

Orthofix is conducting a voluntary recall of the Connector System Large Set Screw (PN: 79-2002) with affected Lot Numbers 001 and 002, and Small Set Screw (PN: 79-2003) with affected Lot Numbers 002, 003 and 004. Through the company's manufacturing controls, size discrepancies were noted with the drive feature for both the large and small sets screws. As a result, it is possible that (1) the set screw drive feature will not accept the Set Screw Driver (PN: 79-1006) or (2) the driver may get wedged in the corners of the drive feature (false bottom) which may lead to a stripped set screw.

Feb 23, 2018 Other Medical Devices View Details →

Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.

Dec 22, 2017 Surgical Instruments View Details →

The infusion sets were manufactured with an incorrect spin collar.

Feb 5, 2018 Surgical Instruments Nationwide View Details →

BMD has identified that the product code/lot number combination identified above may have ineffectively fused tubing and ENFit(TM) connector.

Feb 27, 2018 Diagnostic Equipment Nationwide View Details →

AGB+ Multi Lumen Central Venous Catheterization (CVC) Kit (1) Part Number: AK-42703-P1A; (2) AK-45703-P1A; (3) AK-45703-PB1A; AGB+ Pressure Injectable Multi-Lumen CVC Kit (4) CA-42703-P1A; (5) CA-42854-P1A; (6) CA-45703-P1A; AGB+ Pressure Injectable Quad-Lumen CVC Kit (7) CA-45854-P1A; (8) CDA-42703-P1A; AGB+ Quad-Lumen CVC Kit (9) AK-42854-P1A; (10) AK-45854-P1A; AGB+ Two Lumen CVC Kit (11) AK-42802-P1A; (12) AK-45802-P1A; (13) AK-46702-P1A; (14) AK-47702-P1A; ARROWg+ard BLUE PLUS Pressure Injectable Multi-Lumen CVC Kit (15) CDA-45703-P1A; ARROWg+ard BLUE PLUS Pressure Injectable Quad-Lumen CVC Kit (16) CDA-45854-P1A; ARROWg+ard BLUE PLUS Pressure Injectable Two-Lumen CVC Kit (17) CDA-22122-U1A; (18) CDA-42802-P1A; (19) CDA-42854-P1A; (20) CDA-47702-P1A; ARROWg+ard Blue¿ MAC" Two-Lumen CVC Access Kit (21) CDA-21242-1A; ARROWg+ard Blue¿ PSI Kit (22) CDA-29803-1A; ARROWg+ard Blue¿ Two-Lumen CVC Kit (23) AK-22702-P1A; ARROWg+ard Blue¿ You-Bend" Two- Lumen Hemodialysis Catheterization Kit for High Volume Infusions (24) CDA-25122-U1A; Multi-Lumen CVC Kit with Blue FlexTip(R) Catheter and Sharps Safety Features (25) ASK-12703-PRJ; (26) ASK-15703-PRJ; Multi-Lumen Pressure Injectable Central Venous Catheterization Kit with Blue FlexTip(R) ARROWg+ard Blue PLUS(R) Catheter and Sharps Safety Features (27) ASK-45703-PRH; Pressure Injectable ARROWg+ard Blue Plus(R) Multi-Lumen CVC Kit (28) ASK-45703-PRWJ1; Pressure Injectable ARROWg+ard Blue PLUS(R) Quad-Lumen CVC Kit (29) ASK-42854-PRJ; Pressure Injectable ARROWg+ard Blue PLUS(R) Two-Lumen Central CVC Kit (30) ASK-47702-PPHP; Pressure Injectable ARROWg+ard Blue PLUS(R)Multi-Lumen CVC Kit (31) ASK-45703-PUCD; Pressure Injectable Multi-Lumen CVC Kit (32) ASK-12703-PCA; (33) ASK-15703-PCA; (34) ASK-15703-PHH; (35) ASK-15703-PLV; Pressure Injectable Multi-Lumen CVC kit with Blue Flex Tip¿, ARROWg+ard Blue PLUS¿ Catheter and Sharps Safety Features (36) ASK-42703-PBM; (37) ASK-15703-PRH; (38) ASK-15703-PRWJ; (39) ASK-42703-PRJ; (40) ASK-45703-PRJ; Pressure Injectable Quad-Lumen CVC Kit with Blue FlexTip(R), ARROWg+ard Blue PLUS(R) Catheter, Sharps Safety Features and Maximal Barrier Precautions (41) ASK-42854-PNMM; Pressure Injectable Two Lumen CVC Kit with Blue FlexTip(R), ARROWg+ard Blue PLUS(R) Catheter and Sharps Safety Features (42) ASK-42802-PBM

Arrow International

🏥 Medical Devices Class I - Dangerous

Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.

Dec 22, 2017 Surgical Instruments View Details →

iQ200 Series Urine Microscopy Analyzer may intermittently fail to read urine sample dilution barcode labels causing erroneous results that could delay treatment for health conditions such as hematuria.

Nov 10, 2017 Other Medical Devices Nationwide View Details →