Orthofix is conducting a voluntary recall of the Connector System Large Set Screw (PN: 79-2002) with affected Lot Numbers 001 and 002, and Small Set Screw (PN: 79-2003) with affected Lot Numbers 002, 003 and 004. Through the company's manufacturing controls, size discrepancies were noted with the drive feature for both the large and small sets screws. As a result, it is possible that (1) the set screw drive feature will not accept the Set Screw Driver (PN: 79-1006) or (2) the driver may get wedged in the corners of the drive feature (false bottom) which may lead to a stripped set screw.

Feb 23, 2018 Other Medical Devices View Details โ†’

IntelliVue X3 Patient Monitor.

Philips Electronics North America

๐Ÿฅ Medical Devices Class I - Dangerous

The NBP measurement of Intellivue X3 Patient Monitor shows intermittently only mean values instead of the diastolic and systolic blood pressure values. This is caused by a falsely detected NBP cuff, which is leading to wrong internal NBP setting. Furthermore, occasionally the Monitor shows the Check Touch Input message and the monitor is inoperable with the touch interface.

Nov 17, 2017 Diagnostic Equipment View Details โ†’

The infusion sets were manufactured with an incorrect spin collar.

Feb 5, 2018 Surgical Instruments Nationwide View Details โ†’
๐Ÿฅ Medical Devices Class I - Dangerous

There is possibly a difference between the measured dioptric value of the subjective measurement mode and the objective measurement mode on ARK-1s.

Dec 20, 2017 Diagnostic Equipment Nationwide View Details โ†’

Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.

Dec 22, 2017 Surgical Instruments View Details โ†’

The manufacturer received complaints indicating that the device's central handle holder detaches easily from the handle holder ring on the light head during clinical use. In the event of such detachment, particles from the handle holder ring could fall into the sterile field during a procedure.

Feb 7, 2018 Diagnostic Equipment Nationwide View Details โ†’

The infusion sets were manufactured with an incorrect spin collar.

Feb 5, 2018 Surgical Instruments Nationwide View Details โ†’

BMD has identified that the product code/lot number combination identified above may have ineffectively fused tubing and ENFit(TM) connector.

Feb 27, 2018 Diagnostic Equipment Nationwide View Details โ†’

These products contain latex, but the following statement is not included on any level of product packaging: Caution: This Product Contains Natural Rubber Latex Which May Cause Allergic Reactions.

Mar 15, 2018 Surgical Instruments Nationwide View Details โ†’

Beckman Coulter has determined that there is a potential for under-reporting casts. This can occur if per high-power field (/HPF) units of measurement for casts are selected in the iQ200 software, but the abnormal threshold and/or grading format is set up based on reporting per low-power field (/LPF)* or *per microliter. This may occur during initial method validation or if settings are altered after the initial validation.

Mar 2, 2018 Other Medical Devices View Details โ†’
๐Ÿฅ Medical Devices Class I - Dangerous

A component used within the braking system may break resulting in one or more brake pedals on the bed staying in brake or not being engaged which could result in unwanted bed movement and possible patient or user injury.

Jan 12, 2018 Other Medical Devices Nationwide View Details โ†’

Certain lots of cardiovascular catheters may not be completely sealed and so sterility of the product cannot be guaranteed.

Dec 22, 2017 Surgical Instruments View Details โ†’

These products contain latex, but the following statement is not included on any level of product packaging: Caution: This Product Contains Natural Rubber Latex Which May Cause Allergic Reactions.

Mar 15, 2018 Patient Monitors Nationwide View Details โ†’