lntegra LifeSciences has identified through a number of complaints that the handpiece cable melts following sterilization.

Aug 4, 2020 Surgical Instruments Nationwide View Details →

Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

Aug 25, 2020 Other Medical Devices Nationwide View Details →

The tubes may have been delivered to some users without labels. Users may not be able to identify the tubes without these labels. If samples stored or transported in tubes are tested on certain systems or come into contact with bleach they can produce cyanide gas. The solution in these tubes contains guanidine thiocynate and may put laboratory personnel at risk of exposure to cyanide gas when it comes into contact with bleach or reagents containing bleach.

Jun 3, 2020 Infusion Pumps Nationwide View Details →

The firm received a report of an atypical dataset being generated. When using the cross-localization feature and images from a modality that generates asymmetrical images, the cross-localization reference line may be inaccurately placed on any of the corresponding images that are open.

Sep 10, 2019 Diagnostic Equipment Nationwide View Details →

Incorrect expiration date included in test kit labeling and/or in Substrate component label.

Jul 16, 2020 Other Medical Devices Nationwide View Details →

COVID-19 Interpretive Software issues that may cause: 1) the risk of invalid or inconclusive tests/false negative and potentially increasing the retesting burden on customers. 2) false positive results due to improper vortexing.

Aug 6, 2020 Diagnostic Equipment Nationwide View Details →

Incorrect expiration date included in test kit labeling and/or in Substrate component label.

Jul 16, 2020 Other Medical Devices Nationwide View Details →

Firmware of the Sysmex XN-9000/XN-9100 Interface Module (IM) and of the Track to Rack Module has the potential to mis-associate sample IDs leading to incorrect results or delayed results

Aug 7, 2020 Surgical Instruments Nationwide View Details →

Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

Aug 25, 2020 Other Medical Devices Nationwide View Details →

Mislabeled: WallFlex Biliary RX Uncovered Stent System 10x60mm devices labeled as WallFlexTM Biliary RX Fully Covered Stent System RMV 10x60mm device

Aug 7, 2020 Implants & Prosthetics Nationwide View Details →