All Recalls

95,114 total recalls in our database

Decreased stability for five (5) lots of Calibrator Sets and Calibration Verification Test Sets, resulting in a decrease measured concentration of HCG up to 20%.

Aug 7, 2020 Diagnostic Equipment Nationwide View Details →

The firm has received reports concerning the patient fiducial disk separating from the body and users attempting to re-assemble the device. The use of a re-assembled patient fiducial could lead to inability to navigate or inaccuracies such as improper needle trajectory.

Aug 24, 2020 Other Medical Devices Nationwide View Details →

Instruction For Use (IFU) references incorrect serial number of 90437000. It should state This document applies to ROTAFLOW Consoles as of serial number 94175452 affected by the implementation of the new IEC standard 60601 1 2, 4th edition

Aug 7, 2020 Infusion Pumps Nationwide View Details →

COVID-19 Interpretive Software issues that may cause: 1) the risk of invalid or inconclusive tests/false negative and potentially increasing the retesting burden on customers. 2) false positive results due to improper vortexing.

Aug 6, 2020 Diagnostic Equipment Nationwide View Details →

lntegra LifeSciences has identified through a number of complaints that the handpiece cable melts following sterilization.

Aug 4, 2020 Surgical Instruments Nationwide View Details →

An update to the carryover avoidance technical bulletin to introduce additional steps for reagent carryover avoidance with the Lactate Dehydrogenase assay on RX Instruments. Additional pipette washes can be implemented as described in the technical bulletin. Interference to the Lactate Dehydrogenase (LOH) reagent would be observed as inconsistencies in Quality Control recovery, which may lead to a delay in running patient samples, or erroneous elevated test results.

Aug 11, 2020 Surgical Instruments Nationwide View Details →

An update to the carryover avoidance technical bulletin to introduce additional steps for reagent carryover avoidance with the Lactate Dehydrogenase assay on RX Instruments. Additional pipette washes can be implemented as described in the technical bulletin. Interference to the Lactate Dehydrogenase (LOH) reagent would be observed as inconsistencies in Quality Control recovery, which may lead to a delay in running patient samples, or erroneous elevated test results.

Aug 11, 2020 Surgical Instruments Nationwide View Details →

lntegra LifeSciences has identified through a number of complaints that the handpiece cable melts following sterilization.

Aug 4, 2020 Surgical Instruments Nationwide View Details →

May contain excess glue within the handle of the delivery system, resulting in an inability to fully deploy the graft via the standard method or troubleshooting deployment method provided in the IFU

Aug 11, 2020 Other Medical Devices View Details →

Decreased stability for five (5) lots of Calibrator Sets and Calibration Verification Test Sets, resulting in a decrease measured concentration of HCG up to 20%.

Aug 7, 2020 Diagnostic Equipment Nationwide View Details →

Internal testing at the supplier, revealed that a crimped wire was placed into an air bubble detector (ABD) sensor connector backwards, preventing the crimped wire from locking into the mating wire connector. This intermittent connection may result in false air bubble alarms.

Aug 25, 2020 Other Medical Devices Nationwide View Details →

Firmware of the Sysmex XN-9000/XN-9100 Interface Module (IM) and of the Track to Rack Module has the potential to mis-associate sample IDs leading to incorrect results or delayed results

Aug 7, 2020 Diagnostic Equipment Nationwide View Details →

Firmware of the Sysmex XN-9000/XN-9100 Interface Module (IM) and of the Track to Rack Module has the potential to mis-associate sample IDs leading to incorrect results or delayed results

Aug 7, 2020 Diagnostic Equipment Nationwide View Details →

Sporadically inconsistent discrepant (low bias) glucose results on card lot 01-20095-10. Potential exists for a delay in diagnosis of hyperglycemia or unnecessary treatment for hypoglycemia.

Aug 28, 2020 Diagnostic Equipment Nationwide View Details →