When a Clot Detection Error is generated during the sample aspiration from the Primary Sample Tube the aspirated volume is dispensed into the first empty Secondary Sample Tube. This Secondary Sample Tube is flagged with error 2132 or 1442 and sent to IOM Priority Output Racks to be manually managed. The current error message associated to error 2132 or 1442 recommends that the operator manages these Secondary Sample Tubes according to Laboratory Practice, but it does not clarify that these Secondary Sample Tubes may be diluted with water from the hydraulic circuit of the Aliquoter Module this may lead to reporting of erroneous results if the diluted sample is used for testing.

Jul 14, 2020 Surgical Instruments View Details →
🏥 Medical Devices Class I - Dangerous

The device may detect an incorrect Heater Bag volume which may lead to a 'Supply Bag Line Blocked' alarm during treatment. This alarm may cause the Heater Bag to contain more fluid than expected and the cycler does not recognize the extra fluid is present and it will not make it available for treatment. Not having enough solution to complete treatment may lead to inadequate dialysis which could result in the accumulation of toxins and fluid. Symptoms may include shortness of breath, increased weight gain, and increased blood pressure.

Sep 12, 2020 Other Medical Devices Nationwide View Details →

XTANT Medical, ## mm x ## mm x # mm x # ,Lordotic/Packaged InTice - C, Sterile R, Single Use Only, for the following Reference numbers/ Primary DI Number/Material Grade on Label: Ref: X098-0106-STR DI Number: M697X0980106STR1 Mat.: CP Ti Grade 3, Ref: X098-0107-STR DI Number: M697X0980107STR1 Mat.: CP Ti Grade 4, Ref: X098-0108-STR DI Number: M697X0980108STR1 Mat.: CP Ti Grade 5, Ref: X098-0109-STR DI Number: M697X0980109STR1 Mat.: CP Ti Grade 6, Ref: X098-0110-STR DI Number: M697X0980110STR1 Mat.: CP Ti Grade 7, Ref: X098-0111-STR DI Number: M697X0980111STR1 Mat.: CP Ti Grade 8, Ref: X098-0112-STR DI Number: M697X0980112STR1 Mat.: CP Ti Grade 9, Ref: X098-0205-STR DI Number: M697X0980205STR1 Mat.: CP Ti Grade 10, Ref: X098-0206-STR DI Number: M697X0980206STR1 Mat.: CP Ti Grade 11, Ref: X098-0207-STR DI Number: M697X0980207STR1 Mat.: CP Ti Grade 12, Ref: X098-0208-STR DI Number: M697X0980208STR1 Mat.: CP Ti Grade 13, Ref: X098-0209-STR DI Number: M697X0980209STR1 Mat.: CP Ti Grade 14, Ref: X098-0210-STR DI Number: M697X0980210STR1 Mat.: CP Ti Grade 15, Ref: X098-0211-STR DI Number: M697X0980211STR1 Mat.: CP Ti Grade 16, Ref: X098-0212-STR DI Number: M697X0980212STR1 Mat.: CP Ti Grade 17, Ref: X098-0305-STR DI Number: M697X0980305STR1 Mat.: CP Ti Grade 18, Ref: X098-0306-STR DI Number: M697X0980306STR1 Mat.: CP Ti Grade 19, Ref: X098-0307-STR DI Number: M697X0980307STR1 Mat.: CP Ti Grade 20, Ref: X098-0308-STR DI Number: M697X0980308STR1 Mat.: CP Ti Grade 21, Ref: X098-0309-STR DI Number: M697X0980309STR1 Mat.: CP Ti Grade 22, Ref: X098-0310-STR DI Number: M697X0980310STR1 Mat.: CP Ti Grade 23, Ref: X098-0311-STR DI Number: M697X0980311STR1 Mat.: CP Ti Grade 24, Ref: X098-0312-STR DI Number: M697X0980312STR1 Mat.: CP Ti Grade 25

XTANT Medical

🏥 Medical Devices Class I - Dangerous

Cervical Implants contain a label that incorrectly identifies the grade of titanium used.

Sep 30, 2020 Other Medical Devices View Details →

The use of deionized water rather than distilled water during the manufacturing process, may have resulted in accelerated decreased OD signals for the Positive Control value.

Oct 1, 2020 Infusion Pumps View Details →

The recalling firm has observed an increase in complaints of problems encountered during the initial activation of the device in which the patient and/or the physician is unable or has difficulty activating the pump in order to achieve cylinder inflation.

Sep 24, 2020 Infusion Pumps Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

In-house lab observations and customer reports of overheating and/or thermal damage to the battery pack, create the risk of exposure to smoke or hazardous materials, which may result in burns and/or bronchospasm,

Oct 16, 2020 Patient Monitors Nationwide View Details →

When a Clot Detection Error is generated during the sample aspiration from the Primary Sample Tube the aspirated volume is dispensed into the first empty Secondary Sample Tube. This Secondary Sample Tube is flagged with error 2132 or 1442 and sent to IOM Priority Output Racks to be manually managed. The current error message associated to error 2132 or 1442 recommends that the operator manages these Secondary Sample Tubes according to Laboratory Practice, but it does not clarify that these Secondary Sample Tubes may be diluted with water from the hydraulic circuit of the Aliquoter Module this may lead to reporting of erroneous results if the diluted sample is used for testing.

Jul 14, 2020 Surgical Instruments View Details →

A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

Aug 5, 2020 Other Medical Devices Nationwide View Details →

A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

Aug 5, 2020 Other Medical Devices Nationwide View Details →

A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

Aug 5, 2020 Other Medical Devices Nationwide View Details →

A potential issue of an incorrect CT scan delay timer to be displayed on the gantry Digital Display Panel (DDP) during multi-phase contrast scanning. This could lead the operator to receive unnecessary exposure to radiation.

Aug 5, 2020 Other Medical Devices Nationwide View Details →