Stryker iBur 4.0mm Coarse Diamond Round, Distal Bend - intended to cut bone in the following manner: drilling, reaming, decorticating, shaping, dissecting, shaving, and smoothing for the following medical applications: Neuro; Spine; Ear, Nose, and Throat (ENT)/ Otorhinolaryngology; and Endoscopic applications Ref: 8431-013-040DC

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    GTIN: 07613327501155 Lot Numbers: 22248017 22263017 22334017 22348017 22348027 23016027 23095027 23128017 23163017 23179017 23205017 23205027 23205037 23221017 23311017 24004017 24004027 24004037
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Stryker Corporation
Reason for Recall:
Potential for the product to exhibit temperatures higher than specification where the bur shank meets the distal bushing. Temperatures higher than specification may lead to the potential for minor tissue/structure damage or tissue/structure damage from thermal injury which may need medical/surgical intervention.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
completed

Product Information

Full Description:

Stryker iBur 4.0mm Coarse Diamond Round, Distal Bend - intended to cut bone in the following manner: drilling, reaming, decorticating, shaping, dissecting, shaving, and smoothing for the following medical applications: Neuro; Spine; Ear, Nose, and Throat (ENT)/ Otorhinolaryngology; and Endoscopic applications Ref: 8431-013-040DC

Product Codes/Lot Numbers:

GTIN: 07613327501155 Lot Numbers: 22248017 22263017 22334017 22348017 22348027 23016027 23095027 23128017 23163017 23179017 23205017 23205027 23205037 23221017 23311017 24004017 24004027 24004037

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2728-2024

Related Recalls

It has been identified that the impacted docking station (SN 2521008873) was not product released from manufacturing and may not have completed required testing prior to being shipped to your facility. There is a potential risk of electrical shock due to the device s safety testing being unverifiable.

May 6, 2026 Other Medical Devices Nationwide View Details →

Due to nonconforming products being inadvertently distributed.

Apr 9, 2026 Implants & Prosthetics Nationwide View Details →

Due to a need to update the product labeling (Instructions for Use IFU) as a result of the magnetized surgical tools dislodging markers using during target tissue removal procedures.

Jan 21, 2026 Surgical Instruments Nationwide View Details →