Double Swivel Connector with Suction Port Connector, Airway (Extension) King Systems part 7169 Product Usage: An airway connector is a device intended to connect a breathing gas source to a tracheal tube, tracheostomy tube, or gas mask. The double swivel connector with suction port is an optional connector for a breathing circuit. King System s offers two versions of the double swivel connector, one with a suction port and one without a suction port. The clinical significance of the suction port is that it provides the caregiver the opportunity to perform a secondary procedure if so desired.

Class I - Dangerous
🏥 Medical Devices Recalled: February 17, 2015 King Systems Infusion Pumps Nationwide

What Should You Do?

  1. Check if you have this product:
    Part number 7169 Lot number 1737171
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
King Systems Corp.
Reason for Recall:
Product is mislabeled as Double Swivel Connector with Suction Port and is actually Double Swivel Connector without Suction port. If the incorrect component is not identified prior to clinical use, the incorrect connector would be replaced during the case without risk to the patient and could result in a short delay of the procedure.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Double Swivel Connector with Suction Port Connector, Airway (Extension) King Systems part 7169 Product Usage: An airway connector is a device intended to connect a breathing gas source to a tracheal tube, tracheostomy tube, or gas mask. The double swivel connector with suction port is an optional connector for a breathing circuit. King System s offers two versions of the double swivel connector, one with a suction port and one without a suction port. The clinical significance of the suction port is that it provides the caregiver the opportunity to perform a secondary procedure if so desired.

Product Codes/Lot Numbers:

Part number 7169 Lot number 1737171

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-1361-2015

Related Recalls

KLTD214 airways found inside KLTSD414 packages. The KLTSD414 airway has a lumen for use of a gastric suction tube; the KLTD214 airway does not include a lumen for a gastric suction tube.

Dec 13, 2013 Surgical Instruments View Details →

On December 13, 2012, King Systems initiated a voluntary recall of one (1) case(s) (5) individual products) from one (1) lot [(IV1V3) 62 cases, 310 products]of King LTSD Oropharyngeal Airways because the package label indicated that the airway was a size 5 when in fact the airway in the package was a size 4. When King manufacturers a lot, all of the components are the same size, part number etc. I

Dec 12, 2013 Other Medical Devices Nationwide View Details →

King Systems received a customer complaint indicating that the customer had ordered a breathing circuit with a Latex breathing bag. The product they received contained a Latex breathing bag, but was labeled as non-latex.

Aug 23, 2012 Infusion Pumps Nationwide View Details →