Medical Devices Recalls

Medical equipment, implants, and diagnostic devices

38,779 Total Recalls

The medical procedure trays contain one or more recalled surgical gowns. The gowns were manufactured at locations that did not maintain proper environmental conditions. There is no assurance that the surgical gowns are sterile. An inadequately sterilized surgical gown could compromise a sterile field and increase the risk of a surgical site infection. Due to the configuration of the trays, the recalled gowns may come into contact with other components within the tray posing a risk of cross contamination.

Feb 18, 2020 Other Medical Devices View Details →

The medical procedure trays contain one or more recalled surgical gowns. The gowns were manufactured at locations that did not maintain proper environmental conditions. There is no assurance that the surgical gowns are sterile. An inadequately sterilized surgical gown could compromise a sterile field and increase the risk of a surgical site infection. Due to the configuration of the trays, the recalled gowns may come into contact with other components within the tray posing a risk of cross contamination.

Feb 18, 2020 Other Medical Devices View Details →

A capacitor inside the converter of the Velara X-ray generator may fail after a large number of surges in a short period of time. When this occurs, no image acquisition is possible.

Dec 30, 2019 Other Medical Devices Nationwide View Details →

Potential diff. in the length of the sheath tube and the sheath/probe. A diff. in length could lead to the base of the sheath/probe not being fully seated in the sheath tube which could result in the distal tip of the sheath melting. This could lead to a compromised insulation, leading to unintentional flow of electricity to the patient. The sheath/probe is packaged separately.

Sep 12, 2019 Surgical Instruments View Details →

A software issue could potentially cause the stand and table movements to be blocked.

Feb 14, 2020 Diagnostic Equipment Nationwide View Details →

Due to a nonconformance of product contamination (human blood) of Econocare Plus Waffle Overlay products with the (master) lot # 932213A that may affect a subset of the lot- controlled product (# 932243A). This nonconformance has the potential to expose the end user to materials deemed to be a health risk. Firm is aware of zero instances of contamination in distributed products that have reached consignees.

Jan 19, 2020 Infusion Pumps Nationwide View Details →

Non-sterile product was shipped to customers. Product package is labeled as both "STERILE" and "NON-STERILR" ; the product did not undergo sterilization process and is non-sterile. The usage of a needle that is not sterile could result in infection. Firm is not aware of any reports of patient harm.

Jan 15, 2020 Surgical Instruments Nationwide View Details →

Proximal end of the driver in the affected product may be oversized in varying degrees, potentially making it difficult to connect with and remove from the proximal Nextra implant

Feb 12, 2020 Implants & Prosthetics View Details →

Non-sterile product was shipped to customers. Product package is labeled as both "STERILE" and "NON-STERILR" ; the product did not undergo sterilization process and is non-sterile. The usage of a needle that is not sterile could result in infection. Firm is not aware of any reports of patient harm.

Jan 15, 2020 Surgical Instruments Nationwide View Details →

The firm has become aware that any of the 4 safety catches may exhibit a mechanical failure (break in one of the arms of safety catch), which in certain circumstances may contribute to the side support unintentionally opening and may lead to a potential risk of a patient fall. The patient falling could lead to various types of injuries.

Aug 22, 2019 Other Medical Devices View Details →

Potential for an HVAD System user to mistakenly insert the Battery Charger AC Adapter into an HVAD Controller power port.

Jan 23, 2020 Other Medical Devices View Details →