38,779 Total Recalls

BD Alaris Pump infusion sets (Product Name, Catalog #) BD AlarisTM Pump Infusion Set Vented syringe adapter Smallbore Tubing, Catalog # 10010483; BD AlarisTM Pump Infusion Set 1.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-site, Catalog # 10010453; BD AlarisTM Pump Infusion Set 0.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-site, Catalog # 10010454; BD AlarisTM Pump Infusion Low Sorbing Tubing (PE Lined) Back Check Valve 2 SmartSiteTM Y-sites, Catalog # 10013072; BD AlarisTM Bag Access Non-Vented Back Check Valve 2 SmartSiteTM Y-Sites, Catalog # 10013361; BD AlarisTM Pump Infusion Set Low Sorbing Tubing (PE Lined), Catalog # 10013890; BD AlarisTM Pump Infusion Buerette Set 0.2 Micron Filter Smallbore Tubing SmartSiteTM Port (Burette) SmartSiteTM Y-Site, Catalog # 10015012; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE-Lined), Catalog # 10015862; BD AlarisTM Pump Infusion Blood Set 180 Micron Filter 2 Blunt Spikes, Catalog # 10062818; BD AlarisTM Pump Infusion Buerette Set SmartSiteTM Port (Burette) 3 SmartSiteTM Y-Sites, Catalog # 10821753; BD AlarisTM Pump Infusion Set 2 Back Check Valves 3 SmartSiteTM Y-Sites, Catalog # 11171447; BD AlarisTM Pump Infusion Set Low Sorbing Tubing (PE Lined), Catalog # 11426964; BD AlarisTM Pump Infusion Set 0.2 Micron Filter Back Check Valve Low Sorbing Tubing (PE Lined) 2 SmartSiteTM Y-sites, Catalog # 11532269; BD AlarisTM Pump Infusion Buerette Set 0.2Micron Filter Ball Valve SmartSiteTM Port (Burette) 2 SmartSiteTM Y-Sites, Catalog # 11613191; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined) Back Check Valve 3 SmartSiteTM Y-Sites, Catalog # 10015861A; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined) Bonded TexiumTM ClosedMale LuerWith PrimingCAP, Catalog # 22000-B007T; BD AlarisTM Pump Infusion Set 1.2 Micron Filter, Catalog # 2202-0007; BD AlarisTM Pump Infusion Set, Catalog # 2204-0007; BD AlarisTM Pump Infusion Set Yellow-Striped Microbore Tubing, Catalog # 2206-0007; BD AlarisTM Pump Infusion Set Low Sorbing Tubing (PE Lined), Catalog # 2260-0500; BD AlarisTM Pump Infusion Set Low Sorbing Tubing (PE Lined) Bonded TexiumTM with priming cap, Catalog # 22600-0007T; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined) Bonded TexiumTM with priming cap, Catalog # 22601-B007T; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined) Bonded TexiumTM with priming cap, Catalog # 22602-B007T; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined) Bonded TexiumTM with priming cap, Catalog # 22603-B007T; BD AlarisTM Pump Infusion Set Back Check Valve SmartSiteTM Y-site, Catalog # 24001-0007; BD AlarisTM Pump Infusion Set Half Set SmartSiteTM Y-site, Catalog # 2403-0007; BD AlarisTMPumpInfusionSetSmartsiteTM BagAcessNon-Vented0.2MicronFilterBondedTexiumTMClosedLowSorbingTubing(PELined)MaleLuerwithprimingcapSmartSiteTMY-site, Catalog # 24301-0007T; BD AlarisTM Pump Infusion Buerette Set Smallbore Tubing SmartsiteTM Port (Burette) 3 SmartSiteTM Y-Site, Catalog # 2441-0007; BD AlarisTM Pump Infusion Set Back Check Valve 2 Ganged 3-Way Stopcocks 3 SmartSiteTM Y-sites, Catalog # 2450-0500; BD AlarisTM Pump Infusion Set Low Sorbing Tubing (PE Lined) Back Check Valve 3 SmartSiteTM Y-Sites, Catalog # 24600-0007; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing TexiumTM Back Check Valve 2 SmartSiteTM Y-sites, Catalog # 24601-B007T; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented 0.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-Site, Catalog # 2465-0007; BD AlarisTM Pump Infusion Set SmartSiteTM Bag Access Non-Vented Low Sorbing Tubing (PE Lined), Catalog # 2466-0007.

Becton Dickinson & Company

Class I - Dangerous

Affected infusion sets labeled as free of DEHP actually do contain di(2-ethylhexyl) phthalate (DEHP).

Oct 11, 2023 Surgical Instruments Nationwide View Details →

Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection

Sep 25, 2023 Other Medical Devices Nationwide View Details →

Intera 1.5T

Philips North America

Class I - Dangerous

Potential component failure in the Gradient Coil could product smoke and/or fire.

Oct 23, 2023 Other Medical Devices Nationwide View Details →

Due to an increased risk of degradation of the power entry switch resulting from arcing inside of the power switch that may result in carbon build-up on the switch contacts. The carbon build-up may lead to excess heating inside of the power switch, subsequently leading to deformation of the power switch case. The deformation can create an opportunity for a power switch electrical short. In addition to an electrical short, deformation may result in an open circuit causing the power switch to fail. This event would only occur after the product is in use.

Oct 17, 2023 Diagnostic Equipment Nationwide View Details →
Class I - Dangerous

The Varisoft infusion set is used in conjunction with tandem insulin pumps. The defect reported was damage to the connector piece during manufacturing. This damage results in the connector becoming detached more easily from the insulin set than expected, requiring less force to disconnect than intended. Disconnection, when not detected, for example during sleep, leads to missed basal dosing. which in turn can result in elevated blood glucose and ketone level (nocturnal hyperglycemia). Diabetic ketoacidosis.

Oct 11, 2023 Infusion Pumps Nationwide View Details →
Class I - Dangerous

A high recovery of Iron assay has been observed at some customer sites. Internal studies confirmed the positive shift of Quality Control and patient samples results, up to 15% for Iron Products (Alinity c Iron Reagent REF. 08P3920) to be used on Abbott Alinity Instrument and to 30% for Iron Products (IRON REF. 6K95-41 and IRON REF. 6K95- 30) to be used on Abbott Architect Instrument. When using the affected lots, there is a potential for delay in reporting patient results due to QC failure, also a potential for falsely elevated results.

Sep 29, 2023 Other Medical Devices Nationwide View Details →

Internal testing identified that the GEM Premier PAKs (cartridges) may exhibit an over-recovery (i.e., positive bias) of pO2 results in the low range (at pO2 levels less than 60 mmHg) that are outside of labeled performance specifications for pO2. The positive bias may lead to false positive for medical decision levels at pO2 < 60 mmHg, which may result in failure to detect and/or adequately treat hypoxemia and lead to a delay in treatment. The quality control procedures for the Non-iQM GEM Premier 3000 may not detect the non-conformance.

Sep 29, 2023 Other Medical Devices View Details →

A backwards leak present in the integrated manometer of the patient valve allows for CO2 rebreathing.

Oct 11, 2023 Diagnostic Equipment Nationwide View Details →