During the investigation of four returned Z Flex 270 Steerable Sheaths that were used with cardiac cryoablation balloon catheters, the internal PTFE sheath liners were found to display varying degrees of damage that could pose an embolic risk to a patient.

Sep 6, 2012 Diagnostic Equipment View Details →

Duet TRS may have the potential to injure adjacent anatomical structures which may result in life threatening post-operative complications

Aug 21, 2012 Infusion Pumps View Details →

This notice concerns behavior of the SharePlan that may be unexpected and not clearly described in the user manual. This behavior has not caused patient mistreatment or other incidents. However, the described user actions must be adhered to for best agreement between treatment plan evaluation and the clinical outcome of the delivered treatment. The behavior appears, when importing RFA-files (.asc)

Oct 10, 2011 Infusion Pumps View Details →

A bolt which attaches the oil accumulator within the gantry may fail, resulting in the oil accumulator detaching from the tube housing assembly within the gantry.

Aug 21, 2012 Diagnostic Equipment View Details →

InSight2, version 4.0 and 4.0.1 - DICOM images stored in PACS may be flipped 180¿around vertical axis. InSight FD, version 5.0.1 and 5.0.2 - DICOM images stored in PACS may be lipped 180¿ around vertical axis as well as 180¿ around a horizontal axis.

Sep 14, 2012 Diagnostic Equipment Nationwide View Details →

ConMed Linvatec recalled their 24k Arthroscopy Outflow/Suction Tubing Set (Product Number 24k100)because there is a possibility that the product may have a breach in the Tyvek seal that could potentially compromise the sterility of the contents.

Jul 1, 2011 Implants & Prosthetics Nationwide View Details →

On 1//20/2011 Cordis Corporation , Miami Lakes, FL initiated a recall of their Sleek OTW PTA Dilatation Catheter Model #4261201X Lot #50027149 and Model #4261501X Lot #50026688. Product is incorrectly labeled.

Jan 31, 2011 Surgical Instruments View Details →

A condition can occur during renumbering of the patient database using the DEXCopy feature. When renumbering is being performed using the DEXCopy feature and multiple patients with an identical name are present, the software will assign all subsequent records to the first patient record, resulting in mixed patient records. In order for this problem to occur several conditions need to be met: 1)

Jul 30, 2012 Diagnostic Equipment Nationwide View Details →

Duet TRS may have the potential to injure adjacent anatomical structures which may result in life threatening post-operative complications

Aug 21, 2012 Infusion Pumps View Details →

When positioning the Flex Large 4 Coil (part No. 8625761) off-center in left-right direction as it is used for example for hip and shoulder imaging and, in addition at an off-center position with respect to the head-foot direction, the coil can heat up in the area of the electronic housing (white plastic lids).

Sep 12, 2012 Diagnostic Equipment Nationwide View Details →

Applied Medical is recalling specific lot numbers of its Vascular Catheters because they may have a potential for packaging particulate matter to reside on the product.

Aug 9, 2012 Surgical Instruments Nationwide View Details →

Terumo Cardiovascular Systems (CVS) received two reports of the false back flow alarms for the Terumo¿ Advanced Perfusion System 1 when there was no tubing in the flow sensor. Terumo CVS' investigation found that the voltage level on a circuit board was improperly set in a population of flow modules for Terumo System 1, the sensor operates correctly if the tubing is installed and it is highly unli

Sep 10, 2012 Other Medical Devices Nationwide View Details →

Product was distributed with an incorrect expiration date. Product was labeled with an expiration date of 2013-04 and should have been labeled with 2012-09.

Aug 13, 2012 Other Medical Devices Nationwide View Details →

Applied Medical is recalling specific lot numbers of its Vascular Catheters because they may have a potential for packaging particulate matter to reside on the product.

Aug 9, 2012 Surgical Instruments Nationwide View Details →

On 1/20/2011 Cordis Corporation , Miami Lakes, FL initiated a recall of their Sleek OTW PTA Dilatation Catheter Model #4261201X Lot #50027149 and Model #4261501X Lot #50026688. Product is incorrectly labeled.

Jan 31, 2011 Surgical Instruments View Details →

The SureStart function may not operate in the usual manner, and you may obtain abnormal analysis results when using the cerebral blood flow analysis function.

May 13, 2008 Diagnostic Equipment Nationwide View Details →

An investigation of customer complaints identified that for two product lots, Left Horseshoe Gel Pads were packaged as a Right Horseshoe Gel Pads and vice versa. None of the complaints resulted in a report of patient injuries or an increase in the time to complete the surgical procedure. A physician was consulted to assess patient risk and concluded that there is no potential harm to patients, onl

Jul 27, 2012 Infusion Pumps Nationwide View Details →

Alere San Diego is recalling Alere Triage TOX Drug Screen because there is a possibility that after installing the code chip provided with the affected lots: AMP, BAR, and PCP, the threshold ranges may not be consistently set correctly in all meters.

Jul 12, 2012 Diagnostic Equipment Nationwide View Details →