Beckman Coulter is recalling the UniCel DxH Slidemaker Stainer Coulter Cellular Analysis System to reduce the potential for flammable liquids coming into contact with electrical components in the Stainer module possibly causing a fire.

Aug 4, 2016 Infusion Pumps Nationwide View Details →

The Centricity Laboratory removes free-text notes on a master panel when the user deletes the slave panel. The deletion of a slave panel will (auto slash) the corresponding test (item) results on the master panel. Additionally, the displayed and HL7 results show neither the appropriate abnormal flag value nor the reference range values, when using large_num.g >7 to report numeric results.

Nov 20, 2012 Infusion Pumps View Details →

Software version 1.08 and 1.09 for the Specular Microscope CEM 530 included a change of analysis results feature that was not reviewed and approved by the FDA.

Aug 8, 2016 Infusion Pumps View Details →

Through an error, the labeling failed to include the symbol or other text indicating that the diamond coated tips were single use only. A contributing factor to this error is that in other markets such as Japan, the diamond coated tips are multiple use and are not limited to single use only. The tips are stainless steel with a coating of fine diamond powder. The tips are sold non-sterile and are to be sterilized prior to first use. The tips were cleared as single use only. This problem was discovered during an ongoing, proactive, quality system improvement plan that was initiated by Nakanishi in October 2014. Because the correct instructions for sterilization are not available, it is possible that the devices might not be sterile prior to use. The absence of the single use statement introduces a risk of cross-contamination if the tips are reprocessed and reused.

Jul 8, 2016 Other Medical Devices Nationwide View Details →

Siemens identified an issue with the ratio equation provided on the ADVIA Chemistry XPT System Software Test Definition (TDef) Version 1.0 disks (SMN: 11127343 and 11222123). This issue affects only the ADVIA Chemistry Hemoglobin A1c_3 Automated Pretreatment (A1c_3) results when HbA1c values are reported in International Federation of Clinical Chemistry (IFCC) equivalent units (HbA1cR). The ratio equation used to calculate ADVIA Chemistry Hemoglobin A1c_3 Automated Pretreatment (A1c_3) results in IFCC units contains an error. The error results in falsely depressed HbA1cR results.

Jul 20, 2016 Diagnostic Equipment View Details →

Field failures were reported related to the da Vinci Xi Surgical System EndoWrist Stapler 45 and 30 instruments having an interruption in shaft rotation and / or instrument jaws not opening.

Jul 14, 2016 Surgical Instruments Nationwide View Details →

Terumo Custom Cardiovascular System Cardiovascular Procedure Kits labeled containing Coated Tubing as follows: This product is intended for use only in the extracorporeal circuit for the cardiopulmonary bypass procedures for which the user designed it. This product is a sterile, disposable kit, intended for one-time use for periods up to 6 hours, after which it must be discarded in a manner which is within applicable laws and practices. Terumo Cardiovascular System Cardiovascular Procedure Kits. Each kit is assigned a unique product code/catalog number that is specific to the consignee who has established specifications for the kit. US Product Codes: 72021 72358 71180-01 76021 76022 76023 76024 76025 71801-01 71801-01 71801-01 71801-01 71801-01 74163-03 71296-01 74460-01 74460-01 74460-01 73208-03 74382-01 74382-01 74382-01 74916 74916 74916 70089-07 74063-01 74063-01 74460-01 74460-01 74460-01 74460-01 75252-01 74951 75881 74271-01 71085-02 72742 75314 75368 75368 76095 76095 73339-01 73789 74417 72204 72965-03 73644 73645-01 73700 73861 73871 73901-03 75612 75617 75986 76095 73645-01 73645-01 70099-04 75544 75272 75674 75674 73180 73180 73180 75437 75674 75274 73811 73811 74915 71175-03 73738 76117 75129 75642 75642 72596 72596 72596 75179 74980-01 8340TXC-07 8340TXC-07 8340TXC-07 71875-01 74235-01 74476 75059 75547 75547 74235-01 8351TXC-01 73124 73281-01 73282-01 73874 74477 8340TXC-07 76069 76070 76071 76072 74737 73933 73933 73933 73933 73933 73933 71608-04 75413 74959 75472 75472 75449 75923 75923 73729-01 73730-01 74046-

Terumo Cardiovascular Systems

Class I - Dangerous

Terumo Custom Cardiovascular Procedure Kits are labeled as Xcoating surface coated tubing, but tubing is non-coated

Jul 25, 2016 Other Medical Devices Nationwide View Details →

Through an error, the labeling failed to include the symbol or other text indicating that the diamond coated tips were single use only. A contributing factor to this error is that in other markets such as Japan, the diamond coated tips are multiple use and are not limited to single use only. The tips are stainless steel with a coating of fine diamond powder. The tips are sold non-sterile and are to be sterilized prior to first use. The tips were cleared as single use only. This problem was discovered during an ongoing, proactive, quality system improvement plan that was initiated by Nakanishi in October 2014. Because the correct instructions for sterilization are not available, it is possible that the devices might not be sterile prior to use. The absence of the single use statement introduces a risk of cross-contamination if the tips are reprocessed and reused.

Jul 8, 2016 Infusion Pumps Nationwide View Details →