It is possible that the packaging of the product can be damaged by the prongs on the tube set.
Medical Devices Recalls
Medical equipment, implants, and diagnostic devices
PureFlow B Solution smaller chamber of the two chamber bag can burst electrolyte fluid and cause injury if it comes in contact with the eyes or skin
Dash 4000 Patient Monitoring System is used to monitor physiologic parameter data on adult, pediatric and neonatal patients.
GE Healthcare
The patient monitors may simultaneously restart as designed if all are connected to the same network and a network overload occurs for a prolonged time.
QUADROX-i Neonatal with integrated arterial filter and VHK 11000 (VKMO 11000-USA#QUADROX-i Neo.+Reservoir), Part Number 701055207 The membrane oxygenator QUADROXi Neonatal is intended for use in extracorporeal circulation during cardiopulmonary bypass in cardiac surgery.
Maquet Cardiovascular Us Sales
There is a potential for blood leakage at the blood inlet connector when using the reducing screw adapter 1/4 x 3/16 that may result in clinically relevant loss of prime before patient connection or blood loss during patient connection.
Certain lots of Medex" High Pressure Stopcocks were manufactured with an inner body defect that may result in a leak. Model Number - Lot Number MX4301L - 3538569 MX4331L - 3562377 & 3546826 MX4331R - 3546924
Instructions for Use booklets were not included on the outer pouch
PerkinElmer QSight 210 MD Mass Spectrometer Simplicity 3Q MD v1.0 with Hot Fix 2 Software intended to identify compounds in human samples by ionizing the compound and separating the resulting ions. Part Number: BC004872
PerkinElmer Health Sciences Canada
Under certain conditions when using PerkinElmer QSight 210 MD mass spectrometer with Simplicity 3Q MD and Hotfix 2 software, it is possible for the original data from the last acquired sample to be over-written when the automatic flush is enabled.
PureFlow B Solution smaller chamber of the two chamber bag can burst electrolyte fluid and cause injury if it comes in contact with the eyes or skin
Instructions for Use booklets were not included on the outer pouch
Incorrect measurement results caused by microbial contamination of the product, results in values lower than assigned values
PureFlow B Solution smaller chamber of the two chamber bag can burst electrolyte fluid and cause injury if it comes in contact with the eyes or skin
Solar 8000i Patient Monitoring System is used to monitor physiologic parameter data on adult, pediatric and neonatal patients.
GE Healthcare
The patient monitors may simultaneously restart as designed if all are connected to the same network and a network overload occurs for a prolonged time.
Tosoh Bioscience has become aware of a potential issue with the axis base of the turntable rotation drive motor on the AIA-900 Analyzer. If the tension of the timing belt between the turntable rotation pulley and drive motor is not adjusted correctly, it is possible to increase the lateral load on the motor axis resulting in the inclination and damage of the motor axis. Since January 12, 2017, Tosoh has been inspecting the tension of the timing belt during scheduled preventative maintenance visit and correcting the analyzers where this issue has been observed. If the drive motor fails, the AIA-900 analyzer will cease to function and will be unavailable for use. If this issue occurs, there may be a delay in testing and reporting patient test results. Tosoh has received five (5) complaints related to this issue with no serious injuries reported.
This recall is due to a mandated order from the FDA for stock recovery and return of the imported item.
The firm identified an issue with the basal calculator identified on the Android version of the Insulia application. The bug could lead from low-impact to high-impact hypoglycemia depending on the circumstances. A new update of Insulia is now available (version 1.6.42), which resolves this issue.
Label on the outer carton or the patient labels does not match label on the inner sterile packaging
A safety problem with installation and maintenance could lead to the breakage of the two steel cables that support the equipment to its roof anchor. Due to this, the equipment may fall and cause harm to the patient, user, or third parties.
Potential electric leakage affecting the user.
BD Vacutainer Urine Collection Cups, Cat. No. 364941
Becton Dickinson & Company
BD Vacutainer Urine Collection Cups may contribute to a slight elevation of Red Blood Cell (RBC) counts when used with the Sysmex UF Series Analyzers. BD recommends following Good Clinical Practice (GCP) by using microscopy to confirm an elevated RBC Count in a Urine sample as per CLSI GP16-3A. 29(4) and CAP Checklist on Urinalysis. Product will continue to ship to not impact critical patient care.
Label on the outer carton or the patient labels does not match label on the inner sterile packaging