It is possible that the packaging of the product can be damaged by the prongs on the tube set.

Oct 22, 2018 Diagnostic Equipment View Details β†’

There is a potential for blood leakage at the blood inlet connector when using the reducing screw adapter 1/4 x 3/16 that may result in clinically relevant loss of prime before patient connection or blood loss during patient connection.

Oct 25, 2018 Other Medical Devices Nationwide View Details β†’

Certain lots of Medex" High Pressure Stopcocks were manufactured with an inner body defect that may result in a leak. Model Number - Lot Number MX4301L - 3538569 MX4331L - 3562377 & 3546826 MX4331R - 3546924

Nov 19, 2018 Infusion Pumps View Details β†’

Under certain conditions when using PerkinElmer QSight 210 MD mass spectrometer with Simplicity 3Q MD and Hotfix 2 software, it is possible for the original data from the last acquired sample to be over-written when the automatic flush is enabled.

Sep 24, 2018 Diagnostic Equipment View Details β†’

Tosoh Bioscience has become aware of a potential issue with the axis base of the turntable rotation drive motor on the AIA-900 Analyzer. If the tension of the timing belt between the turntable rotation pulley and drive motor is not adjusted correctly, it is possible to increase the lateral load on the motor axis resulting in the inclination and damage of the motor axis. Since January 12, 2017, Tosoh has been inspecting the tension of the timing belt during scheduled preventative maintenance visit and correcting the analyzers where this issue has been observed. If the drive motor fails, the AIA-900 analyzer will cease to function and will be unavailable for use. If this issue occurs, there may be a delay in testing and reporting patient test results. Tosoh has received five (5) complaints related to this issue with no serious injuries reported.

Oct 5, 2018 Diagnostic Equipment Nationwide View Details β†’
Class I - Dangerous

The firm identified an issue with the basal calculator identified on the Android version of the Insulia application. The bug could lead from low-impact to high-impact hypoglycemia depending on the circumstances. A new update of Insulia is now available (version 1.6.42), which resolves this issue.

Oct 8, 2018 Other Medical Devices View Details β†’
Class I - Dangerous

BD Vacutainer Urine Collection Cups may contribute to a slight elevation of Red Blood Cell (RBC) counts when used with the Sysmex UF Series Analyzers. BD recommends following Good Clinical Practice (GCP) by using microscopy to confirm an elevated RBC Count in a Urine sample as per CLSI GP16-3A. 29(4) and CAP Checklist on Urinalysis. Product will continue to ship to not impact critical patient care.

Aug 30, 2018 Other Medical Devices View Details β†’