Reprocessed Xcel Bladeless Trocar (H12LP) Model # H12LP Reprocessed Endoscopic Trocars12x100mm - Product Usage: Physical Product Description: The Reprocessed Blunt Tip Trocar consists of a radiolucent cannula and obturator sized 12mm in diameter (refer to Figure 1). The Reprocessed Blunt Tip Trocar has an obturator that has a blunt plastic tip that gently moves aside any internal viscera that may be adjacent to the abdominal or thoracic wall. The trocar cannula consists of two seals, an outer integrated removable self-adjusting seal that may accommodate instruments ranging from 5mm to 12mm in diameter, and an internal seal. These seals minimize gas leakage when instruments are inserted or withdrawn through the seal. The stopcock valve provides attachment for gas insufflation and desufflation. The stability plug component, is specific only to the H12LP catalog number. The stability plug (adjustable plug) is placed on the outside of the trocar sleeve (cannula). The stability plug provides suture clips (suture anchors), which can be used to suture the Trocar sleeve in place. Intended Use: Reprocessed Endoscopic Trocars are indicated for use to establish a port of entry for endoscopic instruments in patients requiring minimally invasive surgical procedures. Physical Product Description: The Reprocessed Blunt Tip Trocar consists of a radiolucent cannula and obturator sized 12mm in diameter (refer to Figure 1). The Reprocessed Blunt Tip Trocar has an obturator that has a blunt plastic tip that gently moves aside any internal viscera that may be adjacent to the abdominal or thoracic wall. The trocar cannula consists of two seals, an outer integrated removable self-adjusting seal that may accommodate instruments ranging from 5mm to 12mm in diameter, and an internal seal. These seals minimize gas leakage when instruments are inserted or withdrawn through the seal. The stopcock valve provides attachment for gas insufflation and desufflation. The stability plug component, is specific only to the H12LP catalog number. The stability plug (adjustable plug) is placed on the outside of the trocar sleeve (cannula). The stability plug provides suture clips (suture anchors), which can be used to suture the Trocar sleeve in place. Intended Use: Reprocessed Endoscopic Trocars are indicated for use to establish a port of entry for endoscopic instruments in patients requiring minimally invasive surgical procedures.

Stryker Sustainability Solutions

Class I - Dangerous

Through investigation, it was determined that H12LP Trocars in scope of a previous H12LP recall were distributed to facilities within the distribution chain following the recall execution activities initially performed by distributor.

Jun 19, 2018 Diagnostic Equipment Nationwide View Details β†’

Siemens Healthcare Diagnostics has confirmed that Dimension Vista Lactate Dehydrogenase (LDI) may exhibit an erroneously elevated result when the preceding assay in the reaction cuvette is Lactic Acid (LA). The magnitude of the elevation may be variable. Both quality control and patient samples may be impacted. Incomplete removal of residual lactate dehydrogenase, a component of the LA reagent, has been identified as the cause of the potentially elevated result. A falsely elevated result for lactate dehydrogenase may lead to additional investigations to determine the etiology of tissue damage. Results would be correlated with clinical history and presentation in addition to other diagnostic laboratory testing.

Oct 11, 2018 Diagnostic Equipment Nationwide View Details β†’

This recall has been initiated due to a software defect found in the Guide System software when used with NICO BrainPath ports under certain circumstances. When one trajectory is set with a blue port and another trajectory is set with a gold port, the software defect is triggered when the user switches between these trajectories during a surgical procedure.

Oct 9, 2018 Infusion Pumps Nationwide View Details β†’

There is a potential for blood leakage at the blood inlet connector when using the reducing screw adapter 1/4 x 3/16 that may result in clinically relevant loss of prime before patient connection or blood loss during patient connection.

Oct 25, 2018 Other Medical Devices Nationwide View Details β†’