Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into surgical site

Aug 7, 2023 Other Medical Devices Nationwide View Details →

Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into surgical site

Aug 7, 2023 Other Medical Devices Nationwide View Details →

Potential for the Break-Away Femoral Nozzle the applicator tip connecting the cement cartridge, to disassemble or break off during use, can lead to the potential for loss of function of the ACM system and bio-incompatibility due to components falling into surgical site

Aug 7, 2023 Other Medical Devices Nationwide View Details →

Internal testing on returned product from this lot confirmed that some PDS" II (polydioxanone) Sutures from this lot did not meet tensile strength requirement.

Aug 10, 2023 Other Medical Devices Nationwide View Details →

Gallant HF Cardiac Resynchronization Therapy Defibrillator: HF CRT-D REF CDHFA500Q Neutrino HF Cardiac Resynchronization Therapy Defibrillator: NxT HF CRT-D REF CDHFA600Q Entrant HF Cardiac Resynchronization Therapy Defibrillator : HF CRT-D REF CDHFA300Q The primary function of ICDs and CRT-Ds are to treat life-threatening ventricular tachyarrhythmias via anti-tachycardia pacing (ATP), or cardioversion/defibrillation. Implantable Cardioverter Defibrillators (ICDs) can either be a dual chamber (also known as DR if rate responsive) device that is connected to a right atrial (RA) pacing lead and right ventricular defibrillation lead or single chamber ICD (also known as VR if rate responsive) with only a defibrillation lead in the right ventricle (RV). The ICD, more generally known as an implantable pulse generator (IPG), is typically implanted in a subcutaneous device pocket located in the pectoral region and is attached to the pacing/defibrillator leads that are implanted through the transvenous technique with the distal tips positioned in the RA (dual chamber) and RV. Cardiac Resynchronization Therapy Defibrillator (CRT-D) systems consist of a right atrial (RA) pacing lead, a right ventricular (RV) defibrillation lead, as well as a third lead placed in the coronary venous system overlying the left ventricle (LV) to improve ventricular resynchronization through biventricular pacing for treatment of heart failure. CRT-D devices, more generally known as an implantable pulse generator (IPG), are typically implanted in a subcutaneous device pocket located in the pectoral region and are attached to the pacing/defibrillator leads that are implanted through transvenous technique.

Abbott Medical

🏥 Medical Devices Class I - Dangerous

Due to Bluetooth malfunction on a subset of Implantable Cardioverter Defibrillator (ICD) and Cardia Resynchronization Therapy Defibrillator *CRT-D) devices that were manufactured prior to April 2022 as a result of crystal component issue within the Bluetooth Low Energy (BLE) circuit. This results in the device entering an inductive telemetry only mode with loss of Bluetooth communication. In some instances, thought BLE communication is unavailable, the circuit may remain in a state which draws excessive power affecting battery longevity.

Aug 16, 2023 Implants & Prosthetics View Details →
🏥 Medical Devices Class I - Dangerous

there has been a transcription error in the Instructions for Use (IFU) for the Liquid Assayed Chemistry Control Premium Plus Level 3. For Caeruloplasmin, the one and two standard deviation values printed on the sheet are incorrect, which may lead to misreporting patient results. Target and range values are correct, and risk is mitigated; most clinical labs will use the target and range values in clinical practice.

Aug 3, 2023 Other Medical Devices View Details →

Avanos has received an increase in complaints from customers for COOLIEF RF Generators producing F100 and F101 faults.

Aug 1, 2023 Infusion Pumps View Details →

DR Power Chipper Shredders

Generac Power Systems Inc., of Waukesha, Wisconsin

🏠 Consumer Products Class III - Low Risk

Pieces of metal can come loose from inside the shredder's housing and be ejected, posing a laceration hazard. Also, the hopper can become detached from the shredder, posing a laceration hazard.

Sep 21, 2023 Electronics Nationwide View Details →

Men's clasp beaded bracelets

Unknown Manufacturer

🏠 Consumer Products Class II - Moderate

The clasp on the beaded bracelet contains levels of lead that exceed the federal lead content ban. Lead is toxic if ingested by young children and can cause adverse health effects.

Sep 21, 2023 Other Consumer Products Nationwide View Details →

HONEY JOY Infant Swings

Unknown Manufacturer

🏠 Consumer Products Class II - Moderate

The swing violates the Safe Sleep for Babies Act because the product was marketed for infant sleep and has an incline angle greater than 10 degrees. Infant fatalities have occurred in inclined sleepers, after the infants rolled from their back to their stomach or side while unrestrained, or under other circumstances. The swing also violates the Safety Standard for Infant Swings.

Sep 21, 2023 Furniture Nationwide View Details →