Lack of Assurance of Sterility: Loose crimp applied to the fliptop vial.
All Recalls
95,123 total recalls in our database
"Well at Wallgreens" Regular Strength Antacid Liquid (Alumina/Magnesia/Simethicone/Antacid & Anti Gas); Mint, a)12 oz bottle (NDC 0363-0073-02), b) 26 oz. bottle (NDC 0363-0073-26), Distributed by Walgreens CO., 200 Wilmot Rd, Deerfield, IL 60015.
Tarmac Products, Inc. d.b.a. Axara Pharmaceuticals
Microbial Contamination of Non-Sterile Products: Lot in question had an elevated microbial count outside of specifications and E. Coli contamination.
Lack of Assurance of Sterility: Loose crimp applied to the fliptop vial
Presence of Foreign Tablets/Capsules: One bottle of Percocet 10/325 mg was found to contain a tablet of Endocet 10/25 mg, the generic form.
Chemical contamination: Firm's inspection discovered the presence of 2-phenylphenol in the product due to migration from the cardboard cartons in which the product is packaged.
Acetic Acid Otic Solution, USP, 15 mL bottle, Rx Only, Hi-Tech Pharmacal Co., Inc., Amityville, N.Y. 11701, NDC 50383-889-15, UPC 3 50383-889-15 1.
Hi-Tech Pharmacal Co.
Subpotent Drug: The product/lot is out-of-specification (OOS) for the assay of acetic acid at the 18-month test station.
CGMP Deviations: this product is being recalled because an FDA inspection revealed that it was not manufactured under current good manufacturing practices.
Subpotent Drug: Product did not conform to the 18-month stability test specification for active Free Benzocaine.
Chemical contamination: Firm's inspection discovered the presence of 2-phenylphenol in the product due to migration from the cardboard cartons in which the product is packaged.
Defective Delivery System: Out of Specification (OOS) results for the z-statistic value, which relates to the patients and caregiver ability to remove the release liner from the patch adhesive prior to administration, were obtained.
Stryker Orthopaedics has received a report indicating that the scale of the AxSOS Calibrated Drill Bit 4.3,,X263mm, flat , manufactured by Stryker Osteosynthesis, is incorrect. The incorrect scale could result in the surgeon selecting a screw that is 10mm longer than intended.
Battery level lower then 2.4 volts results in corrupt history log and loss of data for preview therapy's parameters and causes an 11/004 error resulting in the pump not being able to be used.
There is a potential for lead damage due to the use of the lead cap provided in DBS and Dystonia kits. Medtronic has received reports of DBS leads being damaged at the connector end of the lead when the lead cap is used. The connector end of the lead is the end of the lead connected to the lead extension. Tightening or loosening of the setscrew may twist the setscrew connector block and may damag
There have been approximately 2% of the x-ray generators manufactured between February 2012 and November 2012 returned due to errors. These generators showed the type of defect that indicates poor contact of HT transformer power pin. The defect is a bent connector associated with the generator.
GE Healthcare has recently become aware of a Reformat Image Flip Issue associated with GE MR Products. The axial and coronal reformatted images from a sagittal 3D series (such as with applications of FSPGR-3D T1, BRAVO T1, or CUBE T1) of over 126 slices may display a left-to-right image flip . In addition, the acquired sagittal images may be annotated with left-right location annotation revers
When using the SERVO-i on battery power, in a very small number of cases, some battery modules distributed after January 31, 2010 have a shorter battery run time than expected.
Coolant supply lines may leak liquid onto the floor resulting in a slippery surface and fall hazard.
Vital Images, Inc. (Vital Images) received one report about potential user confusion when viewing a brain perfusion scan on Vitrea CT Brain Perfusion 2D when the scan was performed using a wide coverage shuttle acquisition technique. This may result in patient treatment delays, misdiagnosis or mistreatment.
Fastener bolts on the heat exchanger were not properly torqued and part of the heat exchanger can detach from the gantry and hit the inside of the covers and other components of the gantry possibly resulting in the oil conduit breaking, spilling oil within the gantry and outside the system. This issue affects GE Healthcare VCT for Discovery VCT, Discovery RX VCT, and Discovery PET/CT 690, Lightspe
Pump shutting off during use without warning.