A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
All Recalls
95,114 total recalls in our database
The lumen of the Medline Sterile Foley Catheter was found to be blocked by excess lubricious coating material.
Buzzaround XL scooters' Product Usage: mobility
Golden Technologies
Buzzaround XL scooters' front to rear lockup can become unintentionally disengaged due to possible improper fit of the front alignment cup to the rear alignment screw.
During in-process inspection, Terumo Cardiovascular Systems (Terumo CVS) identified exposed basket wire on certain product lots of Sarns Malleable Dual-stage Venous Return Cannulae and Sarns Dual-stage Venous Return Cannulae.
Denlase: Diode Laser Therapy System and Penlase: Dental Laser Therapy System surgical powered. Surgical powered Laser instruments.
China Daheng Group
Failure to provide calibration procedures to purchasers, as required by 21 CFR 1040.11(a)(2). For example, the user manual did not contain calibration procedures for Denlase or Penlase Lasers
A problem has been detected with Philips Model EPIQ 5 and 7 Ultrasound System. The system will report incorrect Doppler velocities if you use High Pulse Repetition Frequency (HPRF) with multiple sample volume gates. While in High Pulse Repetition Frequency (HPRF) in Display Zoom Velocity Scale using manual spectral Doppler trace, the velocities in the velocity results table may be overstated by
A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
Incorrect labeling on specific lots of the Intramedullary Bone Saw. The Saw Blade Assembly was identified as CAM Assembly.
A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
Customers are resetting the default values outside recommended factory settings.
Philips is recalling HeartStart Home and OnSite (HS1) automated external defibrillators (AEDs) because one or both contact pins may be contaminated by residue from the soldering process. This contamination could prevent an adequate connection between the pads cartridge and the AED. If poor contact between the pads cartridge and AED occurs, the device may be unable to deliver therapy in an emergency.
A complaint was received for a discolored All Poly Tibia. Root cause analysis found that the discoloration was the result of free radical oxidation. The oxidation process was advanced prematurely as a result of the machined component being stored in a transparent container exposed to artificial light for six years prior to inert packaging and sterilization of the device.
The products have been identified to contain springs which have been manufactured with type-304 stainless steel rather than the specified titanium alloy.
During in-process inspection, Terumo Cardiovascular Systems (Terumo CVS) identified exposed basket wire on certain product lots of Sarns Malleable Dual-stage Venous Return Cannulae and Sarns Dual-stage Venous Return Cannulae.
KolourOne Brand Panel Array 2.0 and DUO 2.0 PAR LED Light Bulbs
SATCO Products Inc., of Brentwood, NY.
The metal housing/lens assembly can separate from the bulb's base and fall. This poses a risk of injury from impact to bystanders.
Ace Clamp-On LED Work Lights
Unknown Manufacturer
The cord bushing inside the light base could fail, allowing the cord wiring to pull out of the base, exposing bare wire and presenting a shock and fire hazard.
SolarSaveยฎ roof panels
Open Energy Corporation, Inc. and Applied Solar, Inc., of Solana Beach, Calif., are no longer in business.
Fire
My Sweet Love / My Sweet Baby Cuddle Care Baby Doll
Tak Ngai Electronic Toys Co.
The circuit board in the chest of the doll can overheat, causing the surface of the doll to get hot, posing a burn hazard to the consumer.
Bedz King Bunk Beds with Side Ladder
Unknown Manufacturer
A protruding corner post on the bunk beds exceeds the 5mm allowed by industry standard, posing an entrapment hazard.
Children's bed canopies
Unknown Manufacturer
An infant or young child can get entangled at the neck in the canopy's fabric, posing a strangulation hazard.