Serum controls may go out of range low with the ADVIA Centaur ΒΏSystems Folate assay and a shift in whole blood patient may result with kit lots ending in 219 and 223

Mar 25, 2014 Diagnostic Equipment Nationwide View Details β†’

Product does not meet minimum needle attachment strength requirements; thus, the needle can become detached from the suture during use.

Mar 11, 2014 Surgical Instruments Nationwide View Details β†’

There is an issue with the buffers which impacts the quantification of the Hemoglobin F peak. Calibration and Quality control are likely to fail if the affected lots are used.

Apr 8, 2014 Diagnostic Equipment View Details β†’

The sterile barrier in the packaging may be compromised due to cracks in the thermoform tray that may occur during transport of the product in extreme cold weather conditions, in conjunction with mechanical impact.

Apr 14, 2014 Surgical Instruments Nationwide View Details β†’

Mar Cor Purification manufactured Central Water Plant (CWP) reverse osmosis system, models 102, 104 and 106. This correction has been initiated due to a potential situation with a specific lot of the water inlet solenoid valve. The potential exists that the water inlet solenoid valve could cease to function. If this occurs, CWP will stop producing reverse osmosis water.

Apr 24, 2014 Other Medical Devices Nationwide View Details β†’

Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver.

Apr 2, 2014 Diagnostic Equipment View Details β†’

Medical device software may be defective and may cause user-set alarm limits to result in false positive or false negative Oxygen saturation and pulse rate alarm notifications to the caregiver.

Apr 2, 2014 Diagnostic Equipment View Details β†’

Instrument Cover Gas Spring failures. Over time, the gas spring may lose its effectiveness and fail to support the cover in its full or partially open position. This may lead to the cover falling.

Feb 18, 2014 Diagnostic Equipment Nationwide View Details β†’

All configurations of the SS Retractabed, Clinical Contour, made prior to June 7, 2008 may have had insufficient welding on the foot cross tube. This tube is responsible for holding the two support rails together when using the foot side rails and keeps them from separating from the frame. If the weld on the tube breaks, it can lead to bed collapse or the rollers coming out of the channel on t

Apr 18, 2014 Other Medical Devices Nationwide View Details β†’

These lots may not recover within range when tested using certain commercially available controls.

Mar 20, 2014 Diagnostic Equipment Nationwide View Details β†’

This recall provides important new information regarding overinfusion associated with the Medtronic SynchroMed II Implantable Pump. Overinfusion can result in a life-threatening overdose and can also result in drug withdrawal due to premature emptying of the pump. Due to the low reported rate of occurrence of this issue and the inability to predict which pumps may be at risk, Medtronic is not re

Feb 26, 2014 Implants & Prosthetics View Details β†’

All configurations of the SS Retractabed, Clinical Contour, made prior to June 7 2008 may have had insufficient welding on the foot cross tube. This tube is responsible for holding the two support rails together when using the foot side rails and keeps them from separating from the frame. If the weld on the tube breaks, it can lead to bed collapse or the rollers coming out of the channel on th

Apr 18, 2014 Other Medical Devices Nationwide View Details β†’

It has been verified through field use that there are two possible breakages that may occur when using SI50001 Revision D Lock Shaft Inserter, possibly resulting in instrument fragments entering the sterile field: Impact Cap: The impact cap on the Lock Shaft Inserter can shear off under high-impact force during insertion and removal. Pin: The pin used to guide the Lock Shaft Inserter into the ma

Dec 23, 2011 Implants & Prosthetics Nationwide View Details β†’

An anomaly impacts the monitoring system of INOmax DSIR Plus (software 3.0.0). When the integrated pneumatic backup switch is activated with low or no gas flow through the injector module, an intended NO cell failure alarm will occur. In addition, an unintended NO2 cell failure alarm may also occur. The NO/NO2 cell failure alarms are caused by an average NO/NO2 circuit concentration greater tha

Mar 27, 2014 Diagnostic Equipment Nationwide View Details β†’