Failed Content Uniformity Specifications - The lot failed to meet the acceptance criteria for Uniformity of Dosage Units at the time of release for the oxycodone component.
Failed Impurities/Degradation Specification: Out of Specification results for pseudobuprenorphine impurity at the 9-month stability time point.
Brilliance CT System 6/10/16/16P/40 configuration. No packaging, sold as single unit. Computed tomography scanner intended to provide cross sectional images of the human body and visualization of the internal organs.
Philips Medical Systems (Cleveland)
The system has a gap that can appear between the upper and lower tilt stand covers. The fingers may be squeezed if a person was to place them in this region while the gantry was tilting from an angle to zero tilt angle.
Disposable Patient Circuit that allows water to leak into the center gas lumen
Justright Surgical, JustRight 5mm Reload, REFJR-REL25-2.0, Sterile, EO, Rx Only It is a replacement cartridge used when more than one firing is required during a surgery.
Justright Surgical
JustRight Surgical is recalling specific lots of JustRight 5mm Stapler and Reload products because they may deliver poor distal staple formation, past the end of the knife cut.
CareFusion has identified a potential for damage to the power connector on the EnVe and ReVel ventilators due to misconnection by the operator. The input port on the ventilators must have the adapters correctly aligned to function properly. Incorrect alignment may cause the pins in the connector to bend, causing the PTV AC power adapter and/or PTV Auto Lighter Power Cord to be shortened, and pre
Artis zee and Artis zeego systems. x-ray, angiographic system
Siemens Medical Solutions USA
There is a potential problem with Artis zee and Artis zeego systems running software version VC21B and being used in conjunction with the Large Display, in that under certain circumstances, the release of radiation can become blocked unnecessarily.
JustRight Surgical is recalling specific lots of JustRight 5mm Stapler and Reload products because they may deliver poor distal staple formation, past the end of the knife cut.
ICU is recalling the ConMed Stat 2 flow controller because it may deliver a significantly higher flow rate than was intended.
The Ysio Systems with software version VC10 The Ysio enables radiographic and tomographic exposures of the whole Body including: skull, chest, abdomen, and extremities and may be used on pediatric, adult and bariatric patients.
Siemens Medical Solutions USA
Siemens discovered that an unlikely error may occur on the Ysio system with fixed detector in the wall stand. This error may result in line artifacts in the image. If these artifacts appear in the region of interest, the examination may need to be repeated.
UltraStream Chronic Hemodialysis Catheter may develop cracks on the red (arterial) luer during attachment or manipulation.
ICU is recalling the ConMed Stat 2 flow controller because it may deliver a significantly higher flow rate than was intended.
Disposable Patient Circuit that allows water to leak into the center gas lumen
VITROS Immunodiagnostic Products Anti-HCV kit lot 9090 has been observed producing sporadic lower than expected VITROS Anti-HCV test results due to an approximate signal loss of up to 66.2% which can result in unexpected negative test results being obtained for reactive sample fluids (quality control and patient samples).
Nanosphere has received several reports relating to an increased rate of Processing Errors during procedures performed on the Processor SP caused by Tips in Tip Holder Assemblies for the following products and lots of Extraction Trays.
eye-pak 7407 Tray Support Cover REF 8065740745
Alcon Research
The peel pouches of the Tray Support Covers may be insufficiently sealed so that sterility cannot be assured.
BD received some reports of open seals found on the BD Posiflush SF Flush Syringe 10 mL (Ref #306553).
Nanosphere has received several reports relating to an increased rate of Processing Errors during procedures performed on the Processor SP caused by Tips in Tip Holder Assemblies for the following products and lots of Extraction Trays.
Fuze Manual Tilt Wheelchair. Fuze T50, Fuze T20 and Fuze T50 Jr
Pdg Product Design Group
The hex bolt head might shear and cause the axle plate to detach from the lower frame of the wheelchair and could collapse the wheels while in use.