Firm has identified a small number of Oximetry Cables with crossed-internal wires. The effect on performance when these wires are crossed is that when a low SpO2 value is measured, a high SpO2 value would be displayed on the monitoring device. Additionally when a high SpO2 value is measured, a low SpO2 value would be displayed on the monitoring device.

Sep 30, 2014 Implants & Prosthetics Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

Two reports have been received on the 6F launcher Guide Catheter lot (Model Number LA6JR40K; lot No 0007244836} for incorrect usable length of the Guide Catheter. It was reported that the catheters had a usable length of 90 cm instead of 55 cm, which was specified on the packaging label. Usable length is defined as the total length of catheter shaft from the distal end of the strain relief to the

Oct 13, 2014 Surgical Instruments View Details β†’

GE is issuing this recall due to a potential safety issue related to a portion of the system falling onto the patient during a scan due to fasteners being loose that secured the camera to the gantry. GE is updating the Preventative Maintenance procedure and schedule, and added an additional Preventative Maintenance check for loose fasteners on the Nuclear Medicaine systems.

Oct 14, 2014 Diagnostic Equipment Nationwide View Details β†’

GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.

Oct 3, 2014 Diagnostic Equipment View Details β†’

Faulty Automatic Motion Controller (AMC), a problem in the Power On Self Test (POST) error handling was detected, can result in a hazardous movement of the C-arc. system.

Jul 8, 2014 Diagnostic Equipment View Details β†’

An increase in false positive susceptible results on Rapid Neg BP Combo Panel Type 3 and Rapid Neg Urine Combo Panel Type 1 used with MicroScan Microbiology Systems.

Oct 17, 2014 Infusion Pumps Nationwide View Details β†’

GE is issuing this recall due to a potential safety issue related to a portion of the system falling onto the patient during a scan due to fasteners being loose that secured the camera to the gantry. GE is updating the Preventative Maintenance procedure and schedule, and added an additional Preventative Maintenance check for loose fasteners on the Nuclear Medicaine systems.

Oct 14, 2014 Diagnostic Equipment Nationwide View Details β†’

Cardiohelp- i System may have a software issue that can potentially result in an erroneous display of a "Battery Needs Service" message after startup of the units when using either AC or DC power

Oct 17, 2014 Infusion Pumps Nationwide View Details β†’

An increase in false positive susceptible results on Rapid Neg BP Combo Panel Type 3 and Rapid Neg Urine Combo Panel Type 1 used with MicroScan Microbiology Systems.

Oct 17, 2014 Infusion Pumps Nationwide View Details β†’

Incorrect expiration date printed on the MILEX PESSARY KIT packaging

Sep 30, 2014 Surgical Instruments View Details β†’

A typographical error regarding the expiration date was identified in the control module instructions for use.

Oct 20, 2014 Diagnostic Equipment View Details β†’

Faulty Automatic Motion Controller (AMC), a problem in the Power On Self Test (POST) error handling was detected, can result in a hazardous movement of the C-arc. system.

Jul 8, 2014 Diagnostic Equipment View Details β†’

GE Healthcare initiated a field correction because prior revision of components were potentially installed on certain OEC 9800, FlexiView 8800, OEC MiniView 6800 and OEC UroView 2800 systems.

Oct 3, 2014 Diagnostic Equipment View Details β†’

The caster may separate completely from the device frame causing injury to user.

Oct 1, 2014 Other Medical Devices Nationwide View Details β†’

A cable inside the C-arm systems may have been routed in an inappropriate manner. Improper routing of the cable may result in increased wear over time. Without additional measures, the potential exists for a cable inside the C-arm to break which could result in restricted functionality or system failure and an ongoing procedure could be terminated. Additionally, a subgroup of affected C-arm systems will receive a replacement of the cable harness.

Sep 23, 2014 Diagnostic Equipment Nationwide View Details β†’

GE is issuing this recall due to a potential safety issue related to a portion of the system falling onto the patient during a scan due to fasteners being loose that secured the camera to the gantry. GE is updating the Preventative Maintenance procedure and schedule, and added an additional Preventative Maintenance check for loose fasteners on the Nuclear Medicaine systems.

Oct 14, 2014 Diagnostic Equipment Nationwide View Details β†’