Inadequate curing of adhesive, which may cause the two halves of the spheres to separate.
All Recalls
95,114 total recalls in our database
ViewRay received a report that the couch moved unexpectedly into the bore after performing a RTCS reboot.
Risk of false negative results due to microbial growth in the Sample Receiver of one lot of the Alere i Influenza A & B kit
EIZO is recalling the RadiForce LCD Monitors could display abnormally while connecting to particular graphics boards with DisplayPort.
Sorin Stockert Heater-Cooler 3T, 208 V / 60 Hz Temperature control for extracorporeal perfusion of durations up to 6 hours.
Sorin Group USA
Potential colonization of organisms, including Mycobacteria, in Sorin Heater Cooler Devices, if proper disinfection and maintenance is not performed per Instructions for Use.
Sorin Stockert Heater-Cooler 3T, 127 V / 60 Hz Temperature control for extracorporeal perfusion of durations up to 6 hours.
Sorin Group USA
Potential colonization of organisms, including Mycobacteria, in Sorin Heater Cooler Devices, if proper disinfection and maintenance is not performed per Instructions for Use.
Firm received a complaint that the hospital had sent two accession numbers over the same morning and on the Agility side the patient name was incorrect.
Sorin Stockert Heater-Cooler 3T, 200 V / 50Hz / 60 Hz Temperature control for extracorporeal perfusion of durations up to 6 hours.
Sorin Group USA
Potential colonization of organisms, including Mycobacteria, in Sorin Heater Cooler Devices, if proper disinfection and maintenance is not performed per Instructions for Use.
Instruments installed between June 2007 and September 2011 do not contain labeling pursuant to the Food and Drug Administration's (FDA's) Guidance on Laser Products- Conformance with IEC 60825-1 and IEC 60601-2-22 (Laser Notice No. 50).
16mm Chisel Blade; used in the LCP Anterior Ankle Arthodesis Plate System and the Hip Preservation Surgery Set. Orthopedic manual surgical instrument.
Synthes (USA) Products
It was discovered that a 10mm Chisel Blade was etched as a 16mm Chisel Blade.
Medium Bone Plate Forceps was assembled with the incorrect grip arm tip. Potential that the surgeon will be unable to provisionally clamp the plate to the patient's bone.
Potential sterility breach in the packaging.
Accessories to the GYC-1000 laser were missing Laser Aperture labels.
The Supporter toilet armrest has two Fast Nuts fixing the product to the toilet porcelain. The firm has reports of the two Fast Nuts coming loose and causing the Supporter to become unsteady.
The height of one of the three guiding pins of the Helical Blade Inserter for the TFNA is oversized. The Helical Blade Inserter is therefore unable to pass through the Blade/Screw Guide Sleeve (part 03.037.017).
Breas Vivo 50 Home Care Ventilator Product Usage: Respiratory Care
Breas Medical AB
Unintended treatment termination could result from a keypad malfunction in some situations. The device erroneously interprets this as a Stop Treatment Instruction. An alarm will not sound, or be registered. Accessories and monitoring equipment connected to the Vivo 50 will stop functioning as the device enters stand-by mode.
Maquet has identified that in some FLOW-i Anesthesia System Auxiliary O2 and Suction Modules, the suctioning function cannot be activated or controlled by the suction unit on/off switch leading to a decrease or loss of suctioning capability of the modules.
Sorin Stockert Heater-Cooler 3T, 240 V / 60 Hz Temperature control for extracorporeal perfusion of durations up to 6 hours.
Sorin Group USA
Potential colonization of organisms, including Mycobacteria, in Sorin Heater Cooler Devices, if proper disinfection and maintenance is not performed per Instructions for Use.
Oxford Femoral Drill Guide Lateral IM Adapter may have an undersized diameter that can cause an interference with PN: 32-422822, Oxford Microplasty IM Link.
Ronan Bistro Chairs
Unknown Manufacturer
The rear metal legs can bend unexpectedly and cause the chair to become unbalanced, posing a fall hazard to the user.