A defect occurred in the production process of Helioseal F Sealant; the particles in the faulty component seem to be larger than the size defined in the formula. This results in difficulties during extrusion of the material.

Oct 7, 2015 Surgical Instruments Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

1. Device will perform the weekly automated tests hourly, which could cause the therapy capacitors to degrade sooner than intended and 2. While connected to AC or DC power and with no battery installed or the battery installed has a charge level of less than 10%, the Ready for Use (RFU) indicator will not provide the expected low battery indication

Nov 19, 2014 Diagnostic Equipment Nationwide View Details β†’

MRx monitor/defibrillator could reboot at an indeterminate time, potentially causing therapy to be interrupted or delayed

Dec 23, 2014 Diagnostic Equipment Nationwide View Details β†’

ELITech clinical Systems reagents based on Trinder reaction used on the Envoy 500 instrument system are recalled due to potential drug interference. No complaints were received.

Sep 22, 2015 Other Medical Devices Nationwide View Details β†’

Ventilation and alarms of a HAMILTON-G5 ventilator can be suppressed unintentionally after the activation of a suctioning maneuver by the operator; this situation can occur regardless of the selected patient group (neonatal, pediatric and adult).

Apr 22, 2014 Patient Monitors Nationwide View Details β†’

There is a defect in one lot of a buffer, non-specific background staining that has, in some instances, interfered with interpretation of the staining results.

Sep 4, 2015 Diagnostic Equipment Nationwide View Details β†’

Inaccurate distance measurements with magnified projection X-ray images.

Sep 28, 2015 Diagnostic Equipment Nationwide View Details β†’

ELITech clinical Systems reagents based on Trinder reaction used on the Eon 300 instrument system are recalled due to potential drug interference. No complaints were received.

Sep 22, 2015 Other Medical Devices Nationwide View Details β†’

Potentially incorrectly displayed objects when actively deselecting a fused reference dataset.

Sep 21, 2015 Infusion Pumps Nationwide View Details β†’

Bard Peripheral Vascular (BPV) is recalling the Bard Flair Endovascular Stent Graft because of the harm associated with failure to deploy or deployment related issues that could occur during use.

Oct 19, 2015 Implants & Prosthetics Nationwide View Details β†’

The firm is conducting a product correction due to an increase in U90-382 or 6LU condition codes (wash errors) when using VITROS Calibrator Kit 9, Lot 0954.

Sep 28, 2015 Diagnostic Equipment Nationwide View Details β†’

Possibility that the catheter peel-away component hub tabs may prematurely detach when the practitioner begins to peel apart the sheath body from the catheter. Although the issue does not pose a significant risk to the patient, it may cause a delay of treatment when placing the catheter.

Oct 16, 2015 Diagnostic Equipment Nationwide View Details β†’

Software Anomaly during ADD Installation on VITROS 5,1 FS Chemistry Systems using Software Versions 2.2.1 through 2.8. The user modified parameters would not be saved as expected, but remained changed to the default values obtained from the ADD disk.

Sep 10, 2015 Infusion Pumps Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

In AMSCO Small Steam Sterilizers equipped with the CS-iQ feature, the sterilizer software inadvertently prevents the capability to operate the foot pedal, which allows the Operator to open and close the sterilizer door.

Sep 3, 2015 Other Medical Devices Nationwide View Details β†’