When measuring a lesion on an unmagnified mammography image then performing the same measurement on an image magnified by the Hologic imager (different image), the measurements are not the same.

Feb 5, 2016 Other Medical Devices View Details β†’

The rear gradation scale was screen printed upside down on the flowmeter gauge.

Jun 21, 2016 Diagnostic Equipment Nationwide View Details β†’

An increase in the number of da Vinci EndoWrist Stapler complaints where the customer experienced a Stapler Firing Failed message as well as review of da Vinci Xi Surgical System logs found an increased trend

Jul 14, 2016 Surgical Instruments View Details β†’

Software defect, where either an Above Assay Range or an inaccurate value could potentially be reported, in the Stratus CS Acute Care Diagnostics System regarding TestPak calibration and quality control (QC) status when a TestPak is due to expire within 48 hours.

Jun 22, 2016 Diagnostic Equipment View Details β†’

The firm recently identified a quality issue with the Junction box used in the Invacare Bariatric Bed. They discovered that the Junction Box may omit sparks which could result in a fire in the presence of flammable materials.

Mar 15, 2016 Other Medical Devices Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

The following issues have been found in MX 16-slice systems with software version 1.1.4.21426: 1. During the filming operation on MX16-slice console software, the clipboard used for copying and pasting images is not cleared between patients. If the operator fails to copy the current patients images before pasting, a previous patients images may be present in the clipboard and be copied onto the film of the current patient. 2. During the Bolus Tracking scan, if the Auto Voice in Tracker scan is enabled, the Tracker scan will be aborted unexpectedly and the diagnostic scan after the tracker scan needs to be manually started. 3. If the scan protocol with SAS (Spiral Auto Start) function is selected to plan the scan, the SAS option may not be displayed on the Contrast tab of the scan protocol parameter area or the SAS option is displayed but not enabled as pre-configured in the protocol. This issue only occurs on the first helical scan after system startup that applies SAS function

Apr 20, 2016 Diagnostic Equipment View Details β†’

After a few seconds of polishing with moderate force, parts of the OptraPol cup are breaking away. OptraPol Small Flame is also affected. Two complaints were filed referring to OptraPol, claiming that the abrasive polishers wear faster than expected.

Jul 11, 2016 Other Medical Devices View Details β†’

Several customer complaints about amplification performance issues when using different batches of MagSil with the NucliSENS easyMAG extraction platform.

Jul 8, 2016 Diagnostic Equipment Nationwide View Details β†’

Stryker Orthopaedic is voluntarily recalling the Triathlon Modular Handle because analysis revealed that the press fit specifications between the dowel pin and the mating hole in the shaft were not being achieved potentially resulting in disassociation from the instrument.

Jun 23, 2016 Implants & Prosthetics Nationwide View Details β†’

An increase in the number of da Vinci EndoWrist Stapler complaints where the customer experienced a Stapler Firing Failed message as well as review of da Vinci Xi Surgical System logs found an increased trend

Jul 14, 2016 Surgical Instruments View Details β†’

Incorrect CO2 readings with some patient monitors.

Jun 23, 2016 Diagnostic Equipment Nationwide View Details β†’

Football helmets

Xenith LLC, of Detroit, Mich.

🏠 Consumer Products Class II - Moderate

The shells of the football helmets can crack, posing a risk of head injuries to football players.