Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Vista Enzyme 2 calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 10% in comparison to results obtained using earlier calibrator lots.

May 5, 2016 Diagnostic Equipment View Details β†’

A portion of this lot of blood collection tubes was manufactured with approximately twice the expected amount of buffered sodium citrate additive, an anticoagulant.

Jan 16, 2017 Infusion Pumps Nationwide View Details β†’

Chest drains manual vent valve located at the top of affected chest drains could potentially not re-seal after being depressed.

Dec 23, 2016 Infusion Pumps Nationwide View Details β†’

The firm has become aware of a potential device issue where the LIFEPAK 15 device may no longer be able to deliver defibrillation energy due to a potential failure of an internal component (Relay) installed on the Therapy Printed Circuit Board Assembly (PCBA).

Jan 12, 2017 Diagnostic Equipment Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

Terumo Cardiovascular Systems (Terumo CVS) is recalling certain lots of Hercules TM 360 Universal Stabilizing Arms because the two pins that hold the sleeve attached to the distal end of the device may come loose, causing the pins and sleeve to separate from the device. While the arm can still function without the pins and sleeve in place, there is potential for the loose components to fall into the surgical site.

Aug 20, 2014 Infusion Pumps View Details β†’

On June 14, 2016, Greatbatch discovered a significant increase in the number of field complaints for the T5766 Offset Reamer Handle in which the U-joints of the drive chain component seizes during orthopedic procedures rendering the device non-functional. The 2016 failure rate for this failure exceeds the occurrence rate as defined in the DFMEA.

Oct 19, 2016 Implants & Prosthetics Nationwide View Details β†’

Chest drains manual vent valve located at the top of affected chest drains could potentially not re-seal after being depressed.

Dec 23, 2016 Infusion Pumps Nationwide View Details β†’

Chest drains manual vent valve located at the top of affected chest drains could potentially not re-seal after being depressed.

Dec 23, 2016 Infusion Pumps Nationwide View Details β†’

Potential safety issue with the patient bore heating on the Discovery MR450 narrow bore 1.5T MRI. In the event of a RF component failure, typically happening after extended system use, a small area on the bore surface may become warmer than normal. If this happens in an area where there is patient contact with the bore, and proper padding is not used, it may cause a serious burn.

Jan 20, 2017 Implants & Prosthetics Nationwide View Details β†’

There is a remote possibility CentraLink may download an order to the ADVIA Automation System without specifying the sample type. This can occur when an order is received from the LIS without a sample type, requiring that the sample type be set in CentraLink based on the sample type of the test in the order.

Nov 29, 2016 Diagnostic Equipment Nationwide View Details β†’

BrightView XCT

Philips Medical Systems (Cleveland)

πŸ₯ Medical Devices Class I - Dangerous

The intended use listed in the English and localized language IFUs for BrightView XCT systems did not match the intended use documented in the 510K submission.

Dec 23, 2016 Other Medical Devices Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

During development of the VIDAS 3 software version 1.2, some anomalies have been identified and observed to be already present in the current software version VIDAS 3 version 1.1.4. available in the field.

Jan 11, 2017 Other Medical Devices View Details β†’

Contemporary Cutlery knives

Calphalon Corp., of Atlanta, Ga.

🏠 Consumer Products Class III - Low Risk

The blade on Contemporary Cutlery knives can break during use, posing a laceration hazard.

Feb 22, 2017 Furniture Nationwide View Details β†’

Little Live Pets Lil Frog and Lil Frog Lily Pad toys

Moose Toys Proprietary Ltd., of Australia

🏠 Consumer Products Class II - Moderate

When the button batteries are removed from the toy frogs, the battery's cap can become a projectile and the battery's chemicals can leak, posing chemical and injury hazards.

Feb 22, 2017 Children's Products Nationwide View Details β†’

Carbonating bottles

Unknown Manufacturer

🏠 Consumer Products Class II - Moderate

The bottles can burst under pressure, posing an injury hazard to the user or bystanders.

Feb 21, 2017 Other Consumer Products Nationwide View Details β†’