All Recalls

95,083 total recalls in our database

πŸ₯ Medical Devices Class I - Dangerous

The BD MAX System software version 4.44A contains a software anomaly that has the potential to affect some Open System Reagent (OSR) customers utilizing User Defined Protocol (UDP) assays. Customers utilizing only IVD assays are not affected. This anomaly may cause the OSR customer system to incorrectly switch the columns of the truth table on the users display. If the user tries to fix their display data, the display will appear correct however, the database may become incorrect, potentially resulting in incorrect results reporting. BD is able to trace the issue to a limited number of instruments that have software version 4.44A installed. Note that the problem only affects customers that are either creating a new UDP with Result Logic or modifying the Result Logic of an existing UDP.

Jul 29, 2015 Other Medical Devices View Details β†’

Mizuho has discovered that the 5319-37 Wilson Frame Pads have a design deficiency in the construction of their mounting sleeves that may allow the patient to contact the underlying carbon fiber structure of the Wilson frame and could lead to a pressure injury.

Mar 28, 2017 Other Medical Devices View Details β†’

Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components.

Feb 17, 2017 Implants & Prosthetics Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

BD has confirmed reports that lower than expected RFU values were generated on customer BD Viper LT Systems after the installation of software version 3.00H. As RFU values decrease, results approach the assay cutoff threshold which has the potential to impact test results.

Dec 14, 2015 Other Medical Devices View Details β†’

Due to a leak in the detector cooling system, cooling liquid may leak outside the drip tray of the chiller. If this occurs the liquid may drip onto electrical components in the R cabinet located in the technical room, which could lead to damage to the system and potentially cause thermal events such as a burning odor, smoke or fire.

Mar 22, 2017 Other Medical Devices Nationwide View Details β†’

Proteus 235, Proton Therapy System

Ion Beam Applications S.A.

πŸ₯ Medical Devices Class I - Dangerous

In specific circumstances, the user is able to restart an aborted irradiation without having to select the correct partial irradiation data.

Mar 21, 2017 Other Medical Devices View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

During internal testing, Neodent determined that the body diameter (3.8mm) of the Neodent 108.139 CM Exact Intraoral Scan body is not compatible with the platform diameter of CM Implants when the implant is intraosseoussly (subcrestally) positioned.

Mar 13, 2017 Other Medical Devices View Details β†’

Customer reports of the device handset continuing to operate after release of the activation button.

Jan 26, 2017 Other Medical Devices Nationwide View Details β†’

Product labeled as GVL 2 Stat (blades), lot GC32825, was physically packaged with the incorrect size device (GVL 1 Stat (blades)).

Mar 3, 2017 Other Medical Devices Nationwide View Details β†’

Artis zee, Angiographic x-ray system

Siemens Medical Solutions USA

πŸ₯ Medical Devices Class I - Dangerous

Software error - As a result of a software fault in Artis zee systems with software version VD11 and an A100 generator, the possibility exists that following the failure of a tube assembly focus, the Artis system functions properly until the next reactivation. Following reactivation, the system no longer initializes as intended.

Mar 28, 2017 Other Medical Devices View Details β†’