Presence of Foreign Substance: possibility of the presence of metal in the product.
All Recalls
92,900 total recalls in our database
Instructions for use (IFU) is updated to clarify the proper technique and instrumentation to ream the Glenoid, i.e., to include a caution statement that the surgeon should ream on-axis and that reaming off-axis may result in instrument breakage.
Drew Scientific DREW 3-PAC Reagent Kit containing: 5L Diluent, 750 mL Enzymatic Cleaner, and 125 mL Lysing Reagent.
JAS Diagnostics
May result in elevated platelet backgrounds during routine startup/background checks.
Software issue
Software bug which allows parameters to be changed unintentionally during use.
When samples are prepared using the PrepPlus or PrepPlus 2 sample preparation systems and then run on a Flow cytometer, there is an imprecision in the absolute counts on only the first tube in a run.
A field report indicated some units within this lot were missing the bottom pouch seal. The compromised seal is completely missing and is obvious to the user.
Instructions for use (IFU) is updated to clarify the proper technique and instrumentation to ream the Glenoid, i.e., to include a caution statement that the surgeon should ream on-axis and that reaming off-axis may result in instrument breakage.
Mis-pack. A size 6 Left 3DKnee Tibial Insert box and pouch contained a Size 8 right 3Dknee Tibial Insert.
Potential for electric shock in the case of a failure to install the grommets, supplied with the system.
Jelco, Hypodermic needle ProΒΏ needles 19G X1 1/2" 800/CA Model No. EL 1915 & 19G X 2" 600/CA Model No. SB 5021, Rx Only, Sterile EO.
Smiths Medical ASD
Smiths Medical became aware on January 11, 2017, that syringe assemblies provided by Nipro Medical Corporation contained pin holes in the side wall of the hub. The defect was not detected during Smiths Medical incoming inspection. The syringe assemblies were used to manufacture seven (7) finished good lots of Hypodermic Needle ProΒΏ needles, Smiths Medical part numbers EL 1915 and SB5021.
Sterilmed is recalling all lots of specific product codes of unexpired Sterilmed Reprocessed EP Ablation Cables because Sterilmed determined that the cables are Class III devices and thus require, but do not currently have, premarket review and approval.
Boston Scientific Extractor Pro RX-S Retrieval Balloon Catheter 12-15mm Below UPN: M00547340
Boston Scientific
Label on the affected devices incorrectly identifies the injection location as "above" the balloon when it should be below the balloon and "below" the balloon when it should be above the balloon
Medacta GMK HINGE, Tibial Insert Fixed, SIZE 2, HEIGHT 23 mm, REF 02.09.0223H, STERILE EO
Medacta Usa
One lot of product does not include a screw for attachment to the tibial base plate.
Instructions for use (IFU) is updated to clarify the proper technique and instrumentation to ream the Glenoid, i.e., to include a caution statement that the surgeon should ream on-axis and that reaming off-axis may result in instrument breakage.
Nussloch GmbH ASP6025 Tissue Processor
Leica Microsystems
Incorrect labeling for specified voltage for the Alarm Connectors on the rear side of the unit.
Tenaxis Medical ArterX(TM) Surgical Sealant, (a) 4mL, REF 9002, and (b) 5mL REF 9006, STERILE R, Store at 2oC - 8oC Adjunct to sutures in vascular surgery.
Mallinckrodt Manufacturing
Product was improperly labeled leading to improper storage.
Sensis Vibe Systems with Software Version VD10B, Model Numbers 10765502, 10910620, 11007641, 6648161 --- Programmable diagnostic computer,
Siemens Medical Solutions USA
Software error. In Sensis Vibe systems with software version VD10B, a software error can result in: problems generating a report and/ or - information from different examinations of the same patient being combined into one report. --- The error causes information from two examinations to be combined into one report. This does not result in a hazardous situation; however, if the erroneous report has been used for treatment or diagnosis, this can potentially result in an incorrect treatment or diagnosis.
Mis-pack. A size 6 Left 3DKnee Tibial Insert box and pouch contained a Size 8 right 3Dknee Tibial Insert.
Proteus 235 and Proteus ONE proton therapy systems
Ion Beam Applications S.A.
Recall is being initiated to address on-site software installations not being performed consistently with IBA standard operating procedures.