Failed Impurities/Degradation Specifications: Out of specification (OOS) results for unspecified impurity.
All Recalls
95,123 total recalls in our database
AvKARE Valsartan and Hydrochlorothiazide 80 mg/12.5 mg tablets, 90-count bottle, Rx Only, Manufactured for: AvKARE, Inc. Pulaski, TN 38478, NDC 42291-884-90
Avkare Incorporated
CGMP Deviations: Carcinogen impurity detected in API used to manufacture drug product.
AvKARE Valsartan and Hydrochlorothiazide 320 mg/25 mg tablets 90-count bottle, Rx Only, Manufactured for: AvKARE, Inc. Pulaski, TN 38478, NDC 42291-888-90
Avkare Incorporated
CGMP Deviations: Carcinogen impurity detected in API used to manufacture drug product.
Supterpotent Drug
The system side of the power cord may break and expose the electrical conductors leading to the risk of shock.
The system side of the power cord may break and expose the electrical conductors leading to the risk of shock.
VidiStar(TM) PACS & DICOM Viewer Software system
Hitachi Healthcare Americas Corp Informatics Division
The secure filesystem client software used in the interface between the Vidistar PACS and an EHR system may cause intermixed images from multiple patients showing in a single study.
The torque wrench used on the ceiling column assembly during a recent service visit was outside of the torque specification, potentially overtightening the bolts. The overtightening of bolts may compromise the structural integrity of the system which could lead to the OCS disengaging from the ceiling mount and this may cause injury to the patient or the operator.
AutoDELFIA Neonatal immunoreactive trypsin(ogen) (IRT) kit, intended for the quantitative determination of human immunoreactive trypsin(ogen) (IRT) in blood specimens. (UDI: (01)06438147298716(17)190430(10)656479); Product Number: B005-212
PerkinElmer Life and Analytical Sciences, Wallac, OY
The Quality Control Certificate for certain AutoDELFIA Neonatal IRT Kits is missing information required to assess the acceptability of measured control values which may result in a delay in reporting IRT results.
A size 22mm threaded peg was found in the package of a 10mm unit.
Pure Rayz, Light Therapy System, packaging, box, sleeve and user manual. Handheld Wrinkles Reduction Device.
Quasar Bio-Tech
Quasar did not receive FDA clearance for claims of collagen/elastin production as stated on the packaging and in the user manuals.
Vials labeled for the prescriptions contained incorrect lenses
Art-Line Surgery Pack-LF, STERILE, 40 packs each per case.
Medline Industries
Multiple surgical packs were assembled with a non-sterile CHG disk labeled as BIOPATCH" (kit component #52655) attached to the outside of the sterile pack. This may pose potential risk of infection. However, the kits have been in distribution since March 2016. Many of these kits have been used with no reported infections or adverse patient events. In addition, the BIOPATCH is impregnated with CHG, a well-known antiseptic agent with broad-spectrum anti-microbial and antifungal activity.
After receipt of a product complaint for the labeling, it was determined that this device does not have FDA clearance.
Dental implants have incorrect item/lot numbers and size on the inner package labeling. Correct item/lot numbers and size are on the outer package labeling.
GE LOGIQ E9 ultrasound system Product Usage: The device is intended for use by a qualified physician for ultrasound evaluation of Fetal; Abdominal; Pediatric; Small Organ (breast, testes, thyroid); Neonatal Cephalic; Adult Cephalic; Cardiac (adult and pediatric); Peripheral Vascular; Musculo-skeletal Conventional and Superficial; Urology (including prostate); Transrectal; Transvaginal; Transesophageal and Intraoperative (abdominal, thoracic and vascular).
GE Medical Systems Ultrasound & Primary Care Diagnostics, LL
The system side of the power cord may break and expose the electrical conductors leading to the risk of shock.
Incorrect use-by date on the device registration/patient file labels.
PICC Tray, STERILE, 12 packs each per case.
Medline Industries
Multiple surgical packs were assembled with a non-sterile CHG disk labeled as BIOPATCH" (kit component #52655) attached to the outside of the sterile pack. This may pose potential risk of infection. However, the kits have been in distribution since March 2016. Many of these kits have been used with no reported infections or adverse patient events. In addition, the BIOPATCH is impregnated with CHG, a well-known antiseptic agent with broad-spectrum anti-microbial and antifungal activity.
Tibial Alignment Guide, REF 351-10-00 Vantage Fixed Ankle system components for ankle replacements.
Exactech
Exactech is recalling the Tibial Alignment Guide because the Global Trade Item Number (GTIN) on the device is incorrect. The GTIN on the device reads 10885862525629, when it should read 10885862525628.
DRAD-3000E (Radrex-i) TFP-4336W (Wireless FPD)
Canon Medical System, USA
It was found when an operator performs a radiography using the wireless flat panel detector (FPD), a message window was displayed on the monitor stating image transmission was not completed and there was no image. It also showed the OK button to reacquire image data form the FPD, and the Cancel button to cancel the reacquisition. When the operator selects the OK button, the same message window appears. The operator then repeated the same operation several times and finally selected the Cancel button to quit the reacquisition mode.