There is a possibility that the liquid suction pump on some AIA-2000 analyzers may not perform as intended and cause an insufficient volume of wash solution to be removed during the washing step. Incomplete washing of the sample may result in falsely elevated test results for the sandwich assays and falsely decreased test results for the competitive binding assays. Insufficient washing is detectable through review of the calibration data and QC trending. For example, if incomplete washing occurs, the reported values for the zero- calibration rate will be above the acceptance range. The calibration value may shift and the instrument will not calibrate successfully. If this issue occurs, there may be a delay in testing and reporting patient test results. There have been no user or patient injuries reported related to this issue.
All Recalls
95,123 total recalls in our database
Potential electric leakage affecting the user.
BD Vacutainer Specimen Collection Cups, Cat. No. 364975
Becton Dickinson & Company
BD Vacutainer Urine Collection Cups may contribute to a slight elevation of Red Blood Cell (RBC) counts when used with the Sysmex UF Series Analyzers. BD recommends following Good Clinical Practice (GCP) by using microscopy to confirm an elevated RBC Count in a Urine sample as per CLSI GP16-3A. 29(4) and CAP Checklist on Urinalysis. Product will continue to ship to not impact critical patient care.
Experienced accelerated battery depletion and a shortened replacement interval due to latent internal battery malfunctions.
In vitro diagnostic devices, used greater than 6 months after date of manufacture, may have increased concentration times of greater than the specification of 3 hours and up to 24 hours, which may lead to delays in carrying out the subsequent analysis tests.
Panda Wall Mount warmer. Infant radiant warmer
GE Healthcare
Potential electric leakage affecting the user.
COULTER EPICS XL Flow Cytometer COULTER EPICS XL-MCL Flow Cytometer SYSTEM II Software
Beckman Coulter
A manufacturing defect on the amplifier board of the Flow Cytometers my cause signal loss and/or signal drifting resulting in absence of data or a population shift in the data plots. This can impact patient results for any application.
VITROSΒΏ Chemistry Products dLDL Reagent-GENs 26 & 27. In Vitro Diagnostic to quantitatively measure LDL Cholesterol (LDLC) Product Code: 6801728 UDI (10758750006793)
Ortho-Clinical Diagnostics
VITROS Chemistry Products dLDL Reagent GENs 26 and 27, negatively biased results
Tosoh AIA-900 immunoassay Analyzer
Tosoh Bioscience
A software issue may cause the liquid volume detection entries for 2nd and 3rd reagent bottles to be overwritten with the data from the 1st reagent bottle. Tosoh has released software version 2.51 (or later) to fix the problem. This failure is mitigated by the hardware design. The consequence would be a slight delay in testing patient sample or reporting patient result.
Irrisept OR, Finished Bottle Assembly 450 ml STEP 1
Medex Cardio-Pulmonary Inc., d.b.a. Smiths Medical Company
Lack of sterility assurance: leaking containers which could lead to exposure to infectious agents.
After running the calibration curve, the recovery of the IgM kit control results decrease demonstrating a reduction in accuracy within the same day; control results may be out of range one day after running the assay calibration curve. Samples have been shown to be similarly affected.
GLIVARP extendable dining tables
Unknown Manufacturer
The table's glass extension leaf can detach and fall unexpectedly, posing a laceration hazard.
5-Gallon mixing buckets
Zhejiang Focus-On Import & Export, of Binjiang District, China
Young children can fall into buckets and drown. The buckets do not have the required cautionary label warning of the drowning risk posed to young children.
Front air Suspension Bicycle Forks
A-pro Tech Co., Ltd, of Taiwan
The air cartridge can abruptly spring out of the stanchion tube, posing fall and injury risks to the rider.
Vanilla Bean Ice Cream, 3 gallons
Working Cow Homemade
Products may be contaminated with Listeria monocytogenes.
JY Spiderman Ice Cream, 3 gallons
Working Cow Homemade
Products may be contaminated with Listeria monocytogenes.
Ukrop's Cuban Style Sub, NET WT 8.3 OZ (235g), UPC 72251525152
Ukrop's Homestyle Foods
The products may have come into contact with equipment used to process the country ham the supplier recalled for Listeria monocytogenes.
Coffee House Crunch Ice Cream, 3 gallons
Working Cow Homemade
Products may be contaminated with Listeria monocytogenes.
JY Gator Tracks Ice Cream, 3 gallons
Working Cow Homemade
Products may be contaminated with Listeria monocytogenes.
No Sugar Added Chocolate Ice Cream, 3 gallons
Working Cow Homemade
Products may be contaminated with Listeria monocytogenes.