All Recalls

95,123 total recalls in our database

Defective Container: vial defect was identified that could potentially impact the container closure and result in a lack of sterility assurance and/or the potential for glass particles.

Oct 29, 2018 Prescription Drugs View Details β†’

Subpotent Drug: Isotretinoin content results were lower than the specification limit obtained during routing product monitoring.

Dec 7, 2018 Prescription Drugs Nationwide View Details β†’

Failed Impurities/Degradation Specifications:Out of specification for impurities.

Nov 30, 2018 Prescription Drugs Nationwide View Details β†’
πŸ₯ Medical Devices Class I - Dangerous

The VITEKΒΏ 2 Systems Software Version 9.01 software may display incorrect organism identification information as well as the associated Antimicrobial Susceptibility Testing (AST) results when using the VITEKΒΏ 2 FLEXPREP" feature.

Nov 13, 2018 Other Medical Devices Nationwide View Details β†’

Siemens Healthcare Diagnostics has identified an issue with Dimension Vista software v.3.7 and v.3.8.1 that may result in aliquot well contamination. If a test is cancelled by the operator while the instrument is aliquotting the sample, the Dimension Vista instrument may continue to deliver the cancelled sample or vial contents to the aliquot well(s). Future samples may be assigned to the same aliquot well(s) and become contaminated with the existing contents or overflow of the aliquot well may occur potentially contaminating a surrounding well(s). This issue only occurs when an operator manually cancels a test(s) for calibration, quality control (QC) or patient sample while the instrument is in the process of aliquotting the sample.

Oct 16, 2018 Diagnostic Equipment Nationwide View Details β†’

Issue #1 affects Software Versions 6.0 SP7, SP7.0.1, SP7.0.2, SP7.0.3, SP8, SP8.0.1, SP8.0.a and SP8.0.2. When an image is flipped horizontally and vertically, the orientation markers appear correctly on the image to which they were applied. However, once new image rendering happens on this image or series (with scrolling; playing cinΒΏ; maximizing or changing viewports/layouts; or synchronizing viewports and resizing the browser), the new image orientation is correctly maintained but the display of orientation markers can become incorrect. Issue #2 affects Software Versions 6.0 SP7, SP7.0.1, SP7.0.2, SP7.0.3, SP8, SP8.0.1, SP8.0.a, SP8.0.2, SP9 and SP9.0.1. When an image in a series is flipped and then rotated in Zero Footprint Viewer (ZFP), the orientation markers appear correctly on the image to which they were applied. However, once you navigate to another image in the series and the image you navigated to has a different orientation than the prior image from which you navigated, the new image orientation is correctly maintained but the display of orientation markers can become incorrect.

Nov 9, 2018 Infusion Pumps View Details β†’

Table may drift in the roll position while in use

Nov 6, 2018 Diagnostic Equipment Nationwide View Details β†’