There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
Specific lots of reprocessed electrophysiology and ultrasound catheters may contain small residual particulates. If devices with residual particulates on patient-contacting surfaces are used, there is a potential risk of an inflammatory response or systemic infection, and if particulate were to dislodge during use and contact circulating blood and/or the heart, it may produce a granulomatous reaction or thrombus formation, which may lead to cerebral or pulmonary embolism, or deep vein thrombosis.
There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
Reports of vascular graft delamination, which may lead to reduced access flow; cannulation difficulties; bleeding or bruising; and harms related to reintervention procedures, so Instructions for Use will be updated to modify existing warning to 1) further clarify techniques that may contribute to the risk of delamination, 2) Addition of delamination to device-related adverse event section.
There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
The recalled children's loungewear sets violate the mandatory flammability standard for children's sleepwear, posing a risk of burn injuries or death to children.
The recalled test kits contain a bottle of sulfuric acid, which must be in child-resistant packaging, as required by the Poison Prevention Packaging Act. The test kits violate the mandatory standard for child-resistant packaging because the bottle of sulfuric acid is not child-resistant, posing a risk of serious injury or death from poisoning, if the contents are swallowed by young children.
Changzhou Hengze Home Furnishing Co., Ltd, of China
🏠 Consumer Products Class I - Dangerous
The recalled dressers are unstable, if they are not anchored to the wall, posing serious tip-over and entrapment hazards, that can result in injuries or death to children. The dressers violate the mandatory standard as required by the STURDY Act.
The toy airplane inside the egg contains levels of lead that exceed the federal lead content ban. Lead is toxic if ingested by young children and can cause adverse health issues.