Incomplete seals on the sterile package may compromise the sterility
All Recalls
95,114 total recalls in our database
The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip.
WRIGHT EVOLVE Proline Head, Size: +2, OD: 20mm, REF 496H220
Wright Medical Technology
Two lots of EVOLVE Modular Radial Head could have the wrong size product in the package. Both the label and laser marking are incorrect on the affected product.
Centurion-BLOOD CULTURE COLLECTION KIT BP115 BLOOD CULTURE COLLECTION KIT
Centurion Medical Products
Incomplete seals on the sterile package may compromise the sterility
AAMI 3 NON-REINF SURGICAL GOWN XL, Item Code 9545
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
Potential for compromised sterility in breached pouches of specific lots of Reinforced Introducer Sets Maquet 7 Fr., 7.5 Fr. and 8 Fr. IABs.
Centurion-Trays DYNTray, surgicalJ08835 DEBRIDEMENT TRAY W/SAFETY SCAL DYNJ1000 NEWBORN CIRCUMCISION TRAY
Centurion Medical Products
Incomplete seals on the sterile package may compromise the sterility
ROYALSILK LARGE, Gown. Item Code 9518
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip.
AAMI 3 FABREINF SCRUB SURG GWN L NS, Gown. Item Code 90970NA
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
Centurion- Uterine Sound 67465 STERILE SIMS UTERINE SOUND (83360) Y 2019032790
Centurion Medical Products
Incomplete seals on the sterile package may compromise the sterility
ROYALSILK XLARGE, Gown. Item Code 9548
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
Centurion- Trach Kits TC6282G TRACHEOSTOMY CARE TRAY TC7170 LATEX FREE TRACHEOSTOMY CARE TRAY TC7370 TRACHEOSTOMY KIT TC7450 DISPOSABLE TRACH TRAY
Centurion Medical Products
Incomplete seals on the sterile package may compromise the sterility
Incomplete seals on the sterile package may compromise the sterility
GOWN SURG LG W/TOWEL ST BACK, Item Code 9515
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
AAMI 3 NONREINF SURGICAL GOWN 3XL, Item Code 9585
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
WRIGHT EVOLVE Proline Head, Size: +2, OD: 22mm, REF 496H222
Wright Medical Technology
Two lots of EVOLVE Modular Radial Head could have the wrong size product in the package. Both the label and laser marking are incorrect on the affected product.
AAMI 3 NON-REINF SURG GWN XL 2 TWL, Gown Item Code ASG9545
Cardinal Health
The gowns contain an unknown level of bioburden, unknown microbiological flora, and unknown particulate contamination.
The wire guide may be incorrectly loaded into the wire guide holder, leading to the stiff tip of the wire guide being introduced into the patient instead of the flexible tip.
Incomplete seals on the sterile package may compromise the sterility