Due to a distribution error, product from the affected lot was shipped expired.

Mar 26, 2020 Surgical Instruments View Details →

Registering dose and structures in the treatment delivery workflow could result in an alignment discrepancy between the imported previously delivered dose and the displayed patient anatomy and structures. The MRIdian TPDS software shows this misalignment to the user in the predicted dose-volume histogram (DVH). The misalignment impact may not be obvious to the user. During plan re-optimization the previously delivered dose would be incorrectly accounted for by the software. This may result in unexpectedly higher or lower dose than the intended dose calculated for the subsequent treatment plan. When this occurs in the treatment planning workflow, the registration fails to align the dose with the image and the user is unable to proceed.

Nov 18, 2019 Infusion Pumps View Details →

Impacted Welch Allyn products may not meet the Defibrillation Withstand requirements of EN/IEC 60601-2-25 Medical Electrical Equipment.

Mar 18, 2020 Patient Monitors Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

During the sterilization of radial compression devices, some of the inflatable balloons may break or burst, which may result in air leakage and the inability to maintain pressure/compression. This may result in a lack of hemostasis resulting in bleeding or a delay in treatment; the defect is likely to be visually identified by the clinician before use or identified during inflation of the balloon.

Mar 11, 2020 Other Medical Devices Nationwide View Details →

The vertical dimensions of screw-hole position in some standalone cages might be out of range in engineering drawings. A possibility exists of screw pullout, lossening, instability, or less bone-screw engagement than intended by physicians.

Jan 30, 2019 Other Medical Devices Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

Certain iLab Polaris Systems which were upgraded with a previous 2.10 software version (disk batch 629774) contained a bug in which only the True Color Secondary Capture (SC) format will archive Diastolic Hyperemia-Free Ratio data as intended. If either Multi-Frame UltraSound (US) or SC Image Storage formats are used, the DFR data will not be archived and the user will not be notified of this unexpected behavior.

Sep 18, 2019 Diagnostic Equipment View Details →

Tourniquet cuffs are potentially mislabeled. If used may lead to (1) Device misuse during procedure (2) Inadequate Limb Compression Force.

Oct 9, 2019 Other Medical Devices Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

Editing an assay Test Definition and switching to another assay s Test Definition screen without saving the changes using the save button on the screen, may corrupt the settings of the assay s test definition, and Auto-Rerun or Auto-Dilution results may generate a result of Zero (0) for quantitative assays or Negative for qualitative assays if a well of the reagent pack is not calibrated.

Feb 27, 2020 Other Medical Devices Nationwide View Details →

An issue within production process used to package trial kits let to the inclusion of the incorrect bonding agent for the kit. Use of the incorrect bonding agent may lead to increased risk of bond failures.

Feb 25, 2020 Implants & Prosthetics Nationwide View Details →

During initial set-up and/or replacement of the dispenser batteries, the touch dispenser touchscreen can inadvertently lose calibration. This issue can also occur if the touchscreen is pressed when the device is powered on in preparation for a balloon administration. As a result, the touchscreen can become unresponsive and balloon inflation cannot be initiated.

May 23, 2019 Other Medical Devices Nationwide View Details →

The firm has identified that cross-reactivity testing may not meet the claims indicated in the Barbiturates Reagent Chemistry Information Sheet (CIS). The presence of certain compounds in urine may result in false positive or false negative results.

Jun 12, 2019 Diagnostic Equipment Nationwide View Details →