Temperature Abuse: Product was stored at room temperature longer than 6 weeks and was inadvertently distributed instead of discarded
All Recalls
95,025 total recalls in our database
Super-potent Drug: This recall has been initiated due to the elevated presence of minoxidil and biotin.
Metformin HCl Extended Release Tablets, USP, 500 mg, Generic for Glucophage XR, Pkg Size 100, Mfg: Time-Cap, Labs Inc., Farmingdale, NY, Preferred Pharmaceuticals, Anaheim, CA NDC: 68788-6932-01
Preferred Pharmaceuticals
CGMP Deviations: FDA analysis detected N-Nitrosodimethylamine (NDMA) levels in excess of the Acceptable Daily Intake Limit.
Subpotent Drug: active ingredient ethanol tested below label claim and there is presence of undeclared isopropyl alcohol.
Childrens Robitussin Honey Cough and Chest Congestion DM, dextromethorphan (cough suppressant), guaifenesin (expectorant), 4 FL OZ. bottle (118 mL), Distributed by: Pfizer, Madison, NJ 07940 USA, UPC: 50300318760128, NDC: 0031-8760-12.
Glaxosmithkline Consumer Healthcare Holdings
Defective Delivery System: the dosing cups are missing graduations applicable to certain age groups.
Sterile Disposable Connectors ASY 1/2 CONN W/LL STRLE 24 REF/ GTIN for Insert Label:050608000/ 00803622123382
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Failures were found in the temperature measurement function while in the predict mode.
Vein Irrigation Cannula with blunt tip. ASY VIC, STERILE 25/CS REF/ GTIN for Insert Label: VIC/ 00803622133107
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Arrow AutoCAT2 Intra-Aortic Balloon Pump AUTOCAT2 WAVE, Product Code IAP-0500
Arrow International
A potential issue with a component within the above-referenced IABPs may impact the ability of the devices to operate. A Component within the IABP is susceptible to vibration failure resulting in fretting, charring, and discoloration of motor connector wires, which may result in pump alarms for System Error 3 and High Baseline presented on the screen of the IABP, and potential abrupt cessation of function or inability to start the IABP.
Arrow AC3 Optimus Intra-Aortic Balloon Pump AC3 Optimus IABP NA/AJLA, Product Code IAP-0701
Arrow International
A potential issue with a component within the above-referenced IABPs may impact the ability of the devices to operate. A Component within the IABP is susceptible to vibration failure resulting in fretting, charring, and discoloration of motor connector wires, which may result in pump alarms for System Error 3 and High Baseline presented on the screen of the IABP, and potential abrupt cessation of function or inability to start the IABP.
Arrow AutoCAT2 Intra-Aortic Balloon Pump AUTOCAT2 WAVE JAPANESE, Product Code IAP-0500J
Arrow International
A potential issue with a component within the above-referenced IABPs may impact the ability of the devices to operate. A Component within the IABP is susceptible to vibration failure resulting in fretting, charring, and discoloration of motor connector wires, which may result in pump alarms for System Error 3 and High Baseline presented on the screen of the IABP, and potential abrupt cessation of function or inability to start the IABP.
Orthodontic Bracket is mislabeled
Sterile Disposable Connectors ASY RDC Y 1/2X3/8X3/8 STR 24 REF/ GTIN for Insert Label:050529000/ 00803622123351
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
A repair was made to an adapter mold resulting in parts being produced with compliant 10mm ID connections and non-compliant 15mm OD connections. This resulted in facilities with infant resuscitators that connect via the 15mm OD fitting not being able to use those circuits.
Sterile Disposable Connectors ASY STR CONN 1/4 STRLE 24. REF/ GTIN for Insert Label:050504000/ 00803622123221
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Sterile Disposable Connectors ASY S CONN 3/16X1/8 RDR ANLD24 REF/ GTIN for Insert Label:050513000/ 00803622123252
LivaNova USA
The firm has identified through internal tests that the sterile barrier of certain Sterile Standalone Connectors may present a breach. The issue potentially affects component assembled with a specific packaging and is associated to a specific production period.
Respirator Crash Cart Kit
ROi CPS
Roi CPS, LLC has become aware of a labeling error that affects select custom procedure kits. The kits are labeled with an expiration date that is later than that of the soonest kit component to expire in the kits.
Lots of size 8-0 Blue twisted Silk Suture may not meet the stringent full shelf life of 5 years
Unexpected interface driver behavior identified (QC) Results May Be Assigned to an Incorrect Control Lot Number, and lead to the reporting of erroneous patient results if the QC failed but appeared to be passing and the issue is not detected during QC review
VITROS 3600 Immunodiagnostic System Software Versions 3.3.3 and below Product Code: 6802783, Unique Identifier: 10758750002979
Ortho Clinical Diagnostics
Modifications to MicroWell Qualitative Assay Parameters Not Retained- may be inadvertently reset to default in certain circumstances