Olympus Ultrasound Endoscope, Model number: GF-UCT140P-AL5 - Product Usage: used with other supporting equipment for endoscopic real-time ultrasound imaging and endoscopic surgery within the gastrointestinal tract.
Olympus Corporation of the Americas
A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections.
Multiple reasons: 1) Due to wear and tear of pump motor block mechanism - may cause under infusion situations without the pump alarm being generated. 2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Olympus Ultrasound Endoscope, Model number: GF-UC160P-OL5 - Product Usage: used for diagnostic ultrasound imaging or fluid flow analysis of the human body.
Olympus Corporation of the Americas
A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections.
There is a potential that the cable of the Flat panel detector may break during a procedure which may cause the x-ray device to stop before the examination is completed. This could result in a delay with procedure and/or potential damage to the patients blood vessels due to removal without visibility.
Multiple reasons: 1) Due to wear and tear of pump motor block mechanism - may cause under infusion situations without the pump alarm being generated. 2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
Shafts do not pass through the inner cannula of the Anti-Torque Alignment Tube from Lot KTGG due to a manufacturing nonconformance. This could result in a delay of surgery or result in surgical intervention later on.
Olympus Ultrasound Endoscope, Model number: GF-UE160-AL5 - Product Usage: used for endoscopic ultrasonic imaging of the gastrointestinal wall, bile and pancreatic ducts and surrounding organs.
Olympus Corporation of the Americas
A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections.
6PLUS1 Multilevel Saliva Calibrator Set Cortisol Cortisone in Saliva, Order No. 73039 - Product Usage: The kit is used as a test for patients to monitor their cortisol and cortisone levels.
Chromsystems Instruments & Chemicals GmbH
Calibrator lots may not meet stability criteria and could result in increased results of patient samples for cortisone.
B. Braun Introcan Safety IV Catheters, Product codes REF 4252500-01 4252519-01 4252535-01 4252560-01 4252586-01 4251890-01 4252535-01 4252586-01 4251644-01
Janus Trade Group
Distribution of B.Braun Introcan Safety IV catheters without a 510(k) within the United States by JTG.
Multiple reasons: 1) Due to wear and tear of pump motor block mechanism - may cause under infusion situations without the pump alarm being generated. 2) Due to cracks, pump hardware may be damaged by fluid used during the cleaning process.
The firm has become aware of nine reports by a single customer that the software made false positive calls. The investigation determined that the root cause is the higher than expected amber-to-red co-excitation in the assay.
Incorrect filter assemblies in IV administration set.
Heat-cured polymethylmethacrylate (PMMA) milling blank product used to make long-term temporary crowns and bridge restorations has incorrect label. label states Part no. 5336-B1 (98x20mm). However, the item inside the box was Part no. 4302-B1 (95x20mm). An incorrect label may result in compatibility issues when setting up the disc with milling machine fixtures due to size variation.
Missing solder battery connection, which could interrupt power of insulin pump.
MassChrom Cortisol, Cortisone Saliva Control Level II, Order No. 0350 - Product Usage: The kit is used as a test for patients to monitor their cortisol and cortisone levels.
Chromsystems Instruments & Chemicals GmbH
Control lots may not meet stability criteria and could result in increased results of patient samples for cortisone.
Olympus Ultrasound Endoscope, Model number :GF-UM20 - Product Usage: used with other supporting equipment for endoscopic real-time ultrasound imaging and endoscopic surgery within the gastrointestinal tract.
Olympus Corporation of the Americas
A new inspection step was added to the cleaning and disinfection section of the Instructions For Use (IFU) for this device in order to reduce the risk of causing patient infections.