Failed Impurities/ Degradation Specifications - OOS for know impurity Betamethasone 17- propionate.
All Recalls
95,114 total recalls in our database
Non-sterility.Product is being recalled because at labeled storage conditions of 30*C/75% Relative Humidity, growth of Aspergillus penicillioides, a type of fungus, resulted in a breach of the package integrity.
Lack of Assurance of Sterility: Product is being recalled because at labeled storage conditions of 30*C/75% Relative Humidity, there is the potential for growth of Aspergillus penicillioides, a type of fungus, resulting in a breach of the package integrity.
Failed Impurities/ Degradation Specifications - OOS for know impurity Betamethasone 17- propionate.
Losartan Potassium USP, 50 mg, RX Only, Pkg By PD-Rx Pharmaceuticals Incorporated Oklahoma City, OK 73127 a) 60 Tablets NDC: 43063-854-60; b) 90 Tablets NDC: 43063-0854-90
PD-Rx Pharmaceuticals
CGMP deviation: Product found to contain trace amounts of NMBA
Lack of Assurance of Sterility: Product is being recalled because at labeled storage conditions of 30*C/75% Relative Humidity, there is the potential for growth of Aspergillus penicillioides, a type of fungus, resulting in a breach of the package integrity.
Failed Impurities/ Degradation Specifications - OOS for know impurity Betamethasone 17- propionate.
PremierZen Platinum 5000, Packaged in paper packaging with a pill blister, 1 capsule per box, Distributed by New Premier Group Los Angeles CA 90006
Na Na Collection
Marketed without Approved NDA/ANDA: FDA analysis results obtained the presence of tadalafil and/or sildenafil.
Microbial Contamination of Non-Sterile Product:.Product is being recalled because at labeled storage conditions of 30*C/75% Relative Humidity, growth of Aspergillus penicillioides, a type of fungus, resulted in a breach of the package integrity.
CGMP Deviations: Product is being recalled because at labeled storage conditions of 30*C/75% Relative Humidity, there is the potential for growth of Aspergillus penicillioides, a type of fungus, resulting in a breach of the package integrity.
cGMP deviations
Tip Guides are potentially misaligned laterally which could affect the accuracy of the guide system and could cause a delay in procedure and may require another device or alternate surgical method to be used
Due to inappropriate cleaning, some Artis systems show unexpected corrosion of visible belts which are needed to move system parts (e.g. C-Arm), Increased corrosion may lead to a malfunction of the belts which may result in limited functionality of the Artis system up to system failure. Unintended movement of the C-Arm may cause a hazardous situation to the patient, operator, or staff members and may result in a situation where it is necessary to cancel clinical treatment or to continue treatment on an alternative system
Power Wheelchair
Merits Holdings Co.
Seat baseplate pin has broken in the field.
Siemens has become aware of a potential issue with software version VE20C. Planned procedures may have to be terminated and performed on an alternative x-ray system.
VITROSΒΏ Black Reference Slides CATALOG #: J02316 - Product Usage: The Black Reference Slide is a part/ tool used in the reflectometer correction factor adjustment procedure.
Ortho-Clinical Diagnostics
Delayed results. Ortho confirmed that two lots of VITROS Black Reference Slides are incorrectly labelled as White Reference Slides. If the customer fails to notice both the product name or the unexpected color of the slides and tries to use Black Reference Slides as White Reference Slides, the Correction Factor test will fail - and the analyzer will not be able to produce results for any assays other than sodium, potassium, and chloride. If the customer doesnt have any White Reference Slides in reserve, they cant run the Correction Factor test correctly and get the analyzer running again until they get more White Reference Slides delivered. This could lead to a delay in results for all Vitros assays except for sodium, potassium, and chloride.
Potential for pinholes (sterile barrier breach) on the edge of the pouch to potentially render the device non-sterile, and may result in a post-operative infection
On 02/26/2021, it was found that there were incorrectly packaged Dilator sets in Finished Goods. On 03/1/2021, it was confirmed that 14 kits containing the impacted products had been distributed to the field.
Scooter
Merits Holdings Co.
Seat baseplate pin has broken in the field.
InCore Lapidus Disposable Kit 28mm Left, Part Number: IC-LAP-28L - Product Usage: Intended as a three-part construct intended for internal fixation for First Metatarsocuneiform arthrodesis.
Nextremity Solutions
Product could potentially contain an undersized inner diameter of the 40mm drill bushing which result in not allowing the drill bit to pass through the drill bushing, causing inability of surgeon to complete surgical procedure as intended