Instructions for Use (IFU) (Instructions for Use) indicate compliance with ANSI/AAMI EC53:2013/(R)2020 ECG trunk cables and patient leadwires. Section 5.3.9 of the standard requires the device to withstand, without breakdown , an application of, 5,000 V d.c. when used with a defibrillator at a voltage above its maximum threshold, Claravue does not meet the specification and delivers an inefficient electrical charge which may result in an ineffective defibrillation.
Siemens Healthcare Diagnostics Inc. has confirmed the potential for reagent carryover impacting quality control (QC), patient samples, and calibrator results.
The internal part in the valve can malfunction while in use, causing loss of inflation and thermal protection, posing a risk of hypothermia to the consumer.
The riding mowers can fail to come to a complete stop and continue to move at a speed of about one mile per hour when the clutch/brake pedal is fully depressed, posing a low speed crash hazard.
The products are dietary supplements containing iron which must be in child-resistant packaging as required by the Poison Prevention Packaging Act (PPPA). The packaging of the products is not child-resistant, posing a risk of poisoning if the contents are swallowed by young children.
The products contain the substance lidocaine which must be in child resistant packaging as required by the Poison Prevention Packaging Act (PPPA). The packaging of the products is not child resistant, posing a risk of poisoning if the contents are swallowed or placed on the skin of young children.