Frozen french fries is being recalled due to undeclared wheat.

Jun 7, 2022 Produce View Details →

CGMP Deviations: lots made with same active pharmaceutical ingredient (API) as lots that were rejected due to manufacturing issues that could cause the product to be out of specification for impurities.

Jun 3, 2022 Prescription Drugs Nationwide View Details →

Lack of Assurance of Sterility: Manufacturing deviation which was reported due to a microbial excursion

Jun 10, 2022 Prescription Drugs Nationwide View Details →

Part (A-rubber) intended for a different model of gastrointestinal videoscope may have been used when replacing part on GIF-HQ190 during the last repair at Olympus. An Incorrect A-rubber fits tighter on the GIF-HQ190 which would not meet the intended design specifications

Apr 22, 2022 Diagnostic Equipment Nationwide View Details →

Colonovideoscope Model CF-H180AL

Olympus Corporation of the Americas

🏥 Medical Devices Class I - Dangerous

A (Camera unit) CCD intended for a different model of colonoscope may have been installed in the CF-H180AL, viewing angle would be narrower than a normal CF-H180AL and the use of EndoTherapy devices may stick out (approximately 1.4 mm) further than normal protrusion,could lead to patient injury; specifically, mucosal damage that could result in hemorrhage or bleeding

Apr 22, 2022 Other Medical Devices Nationwide View Details →

Mislabeled: Product labeled as Intergard Woven Straight graft REF IGW0032-30, D: 8 mm, L: 30 cm, contained an Intergard Woven Straight graft of D: 32 mm and L: 30 cm

Apr 29, 2022 Other Medical Devices Nationwide View Details →

Multiple issues with the potential for interruption of therapy or over-infusion: 1. Primary Audible Alarm (PAA), 2. Unanticipated Depleted Battery Alarms, 3. Time Base Alarm, 4. Intermittent Volume Over Time (IVOT) - Infusion Continues after System Failure, 5. Clearing of Program Volume Delivered (PVD), 6. False Alarm for Rate Below Recommended Minimum for Syringe Size, 7. Incorrect Bolus or Loading Dose Time Display, 8. Domain Name Server (DNS) Port 1001

Apr 18, 2022 Surgical Instruments Nationwide View Details →

Multiple issues with the potential for interruption of therapy or over-infusion: 1. Primary Audible Alarm (PAA), 2. Unanticipated Depleted Battery Alarms, 3. Time Base Alarm, 4. Intermittent Volume Over Time (IVOT) - Infusion Continues after System Failure, 5. Clearing of Program Volume Delivered (PVD), 6. False Alarm for Rate Below Recommended Minimum for Syringe Size, 7. Incorrect Bolus or Loading Dose Time Display, 8. Domain Name Server (DNS) Port 1001

Apr 18, 2022 Surgical Instruments Nationwide View Details →
🏥 Medical Devices Class I - Dangerous

Due to device (preloaded intraocular lens) mislabeling, associated with partial mixing of product during overlapping manufacturing runs, and attributed to improper manufacturing line clearance.

May 11, 2022 Infusion Pumps View Details →