Fogarty Adherent Clot Catheter Model Numbers 1408010 and 140806 Product Usage: The Fogarty adherent clot catheters are designed to effectively remove clot material in the peripheral vasculature. The catheters are indicated for the removal of emboli and thrombi from native arteries or synthetic grafts. The device are designed to facilitate clots too resistant to be removed by an elastomeric balloon. The device features a spiral-shaped, latex-covered stainless steel cable that assumes a corkscrew shape when retracted, greatly expanding the surface areas to entrap fibrous material. The device is 80 cm in length and is available in 4F-6F diameters.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Lots 60439817 and 60439818
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Edwards Lifesciences, LLC
Reason for Recall:
The diameter of the Fogarty Catheter balloon, measures 6mm instead of 10mm.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Fogarty Adherent Clot Catheter Model Numbers 1408010 and 140806 Product Usage: The Fogarty adherent clot catheters are designed to effectively remove clot material in the peripheral vasculature. The catheters are indicated for the removal of emboli and thrombi from native arteries or synthetic grafts. The device are designed to facilitate clots too resistant to be removed by an elastomeric balloon. The device features a spiral-shaped, latex-covered stainless steel cable that assumes a corkscrew shape when retracted, greatly expanding the surface areas to entrap fibrous material. The device is 80 cm in length and is available in 4F-6F diameters.

Product Codes/Lot Numbers:

Lots 60439817 and 60439818

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-3077-2017

Related Recalls

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 Other Medical Devices Nationwide View Details β†’

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 Other Medical Devices Nationwide View Details β†’

due to complaints received for 3mm to 4mm section wire exposed/protruding from the outside of the cannula body.

May 14, 2025 Other Medical Devices Nationwide View Details β†’