Software: Syngo.via RT Image Suite software version VA30_SP02 with license T_RT_IMAGE_SUITE_PAT_MARK Intended Use: used as an advanced application on a SOM10 scanner SMN: 10496180
Class I - DangerousWhat Should You Do?
- Check if you have this product: Serial Numbers: 100418 100419 100420 100421 100641 100642 100643 100644 100645 100704 100713 100735 100811 100812 100813 100814 101724 102013 102031 102108 102305 102369 130125 130140 130331 130335 130628 130751 130848 130874 131012 131169 131247 131284 131325 131336 131360 131503 131578 131589 131801 131966 132011 132061 132102 132108 132136 132231 132595 132729 222224 222411 222417 222475 222491 222539 222563 222601 222638 222686 222946 223004 223084 451001
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Siemens Medical Solutions USA, Inc
- Reason for Recall:
- Calibration offset between the central CT image plane and the external RT lasers has been set automatically to the factory default of 50.00 cm, if the misadjustment of the offset value is not recognized during the subsequent treatment planning process or remains undetected during the position verification at the treatment system (e.g. linear accelerator), this can potentially result in an incorrect dose or dose applied to the wrong location
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Software: Syngo.via RT Image Suite software version VA30_SP02 with license T_RT_IMAGE_SUITE_PAT_MARK Intended Use: used as an advanced application on a SOM10 scanner SMN: 10496180
Product Codes/Lot Numbers:
Serial Numbers: 100418 100419 100420 100421 100641 100642 100643 100644 100645 100704 100713 100735 100811 100812 100813 100814 101724 102013 102031 102108 102305 102369 130125 130140 130331 130335 130628 130751 130848 130874 131012 131169 131247 131284 131325 131336 131360 131503 131578 131589 131801 131966 132011 132061 132102 132108 132136 132231 132595 132729 222224 222411 222417 222475 222491 222539 222563 222601 222638 222686 222946 223004 223084 451001
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-3005-2020
Related Recalls
MAMMOMAT Inspiration;
Siemens Medical Solutions USA
There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.
MAMMOMAT Fusion;
Siemens Medical Solutions USA
There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.
MAMMOMAT Revelation;
Siemens Medical Solutions USA
There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.