O-Two Adult Ventilation Timer, MODEL #(s): 01BM1000-CS, 01BM3201-MOTP-CS, 01BM3201-MOTL-CS, CATALOG #(s): 01BM1000 --- INTENDED USE: The Adult Ventilation Timer is intended to guide the rescuer to provide ventilations at a rate appropriate for adult patients
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot #s: 079810; 078734, 081071, 140411, 141117, 140719, 140506, 130117 Expiration date: Jul.2016
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- O-Two Medical Technologies, Inc.
- Reason for Recall:
- Malfunction of an O-Two Adult Ventilation Timer, where the flash rate of the malfunctioning device was reported to be twice that of the rate noted on the label.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
O-Two Adult Ventilation Timer, MODEL #(s): 01BM1000-CS, 01BM3201-MOTP-CS, 01BM3201-MOTL-CS, CATALOG #(s): 01BM1000 --- INTENDED USE: The Adult Ventilation Timer is intended to guide the rescuer to provide ventilations at a rate appropriate for adult patients
Product Codes/Lot Numbers:
Lot #s: 079810; 078734, 081071, 140411, 141117, 140719, 140506, 130117 Expiration date: Jul.2016
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2705-2017
Related Recalls
e700 Automatic Transport Ventilator, Model Number 01EVE700
O-Two Medical Technologies
There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.
e600 Automatic Transport Ventilator, Model Number 01EVE600
O-Two Medical Technologies
There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.
e500 Automatic Transport Ventilator, Model Number 01EVE500
O-Two Medical Technologies
There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.