MAGNETOM Lumina (DE). Model Number: 11344916.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Model Number: 11344916. UDI Numbers: (01)04056869230740(21)196458, (01)04056869230740(21)196591, (01)04056869230740(21)196655, (01)04056869230740(21)196355, (01)04056869230740(21)196733, (01)04056869230740(21)196668, (01)04056869230740(21)196477, (01)04056869230740(21)196343, (01)04056869230740(21)196553, (01)04056869230740(21)196519, (01)04056869230740(21)196366, (01)04056869230740(21)196782, (01)04056869230740(21)196617, (01)04056869230740(21)196684, (01)04056869230740(21)196502, (01)04056869230740(21)196539, (01)04056869230740(21)196280, (01)04056869230740(21)196626, (01)04056869230740(21)196511, (01)04056869230740(21)196643, (01)04056869230740(21)196796, (01)04056869230740(21)196551, (01)04056869230740(21)196495, (01)04056869230740(21)196741, (01)04056869230740(21)196621, (01)04056869230740(21)196611, (01)04056869230740(21)196544, (01)04056869230740(21)196724, (01)04056869230740(21)196776, (01)04056869230740(21)196752, (01)04056869230740(21)196372, (01)04056869230740(21)196350, (01)04056869230740(21)196841, (01)04056869230740(21)196252, (01)04056869230740(21)196508, (01)04056869230740(21)196332, (01)04056869230740(21)196496, (01)04056869230740(21)196753, (01)04056869230740(21)196375, (01)04056869230740(21)196738, (01)04056869230740(21)196260, (01)04056869230740(21)196470, (01)04056869230740(21)196765, (01)04056869230740(21)196334, (01)04056869230740(21)196288, (01)04056869230740(21)196409, (01)04056869230740(21)196737, (01)04056869230740(21)196286, (01)04056869230740(21)196604, (01)04056869230740(21)196446, (01)04056869230740(21)196362, (01)04056869230740(21)196518, (01)04056869230740(21)196619, (01)04056869230740(21)196450, (01)04056869230740(21)196678, (01)04056869230740(21)196349, (01)04056869230740(21)196261, (01)04056869230740(21)196415, (01)04056869230740(21)196386, (01)04056869230740(21)196391, (01)04056869230740(21)196537, (01)04056869230740(21)196649, (01)04056869230740(21)196411, (01)04056869230740(21)196353, (01)04056869230740(21)196629, (01)04056869230740(21)196403, (01)04056869230740(21)196529, (01)04056869230740(21)196622, (01)04056869230740(21)196414, (01)04056869230740(21)196778, (01)04056869230740(21)196308, (01)04056869230740(21)196768, (01)04056869230740(21)196791, (01)04056869230740(21)196832, (01)04056869230740(21)196606, (01)04056869230740(21)196240, (01)04056869230740(21)196730, (01)04056869230740(21)196360, (01)04056869230740(21)196466, (01)04056869230740(21)196831, (01)04056869230740(21)196789, (01)04056869230740(21)196780, (01)04056869230740(21)196779, (01)04056869230740(21)196405, (01)04056869230740(21)196625, (01)04056869230740(21)196376, (01)04056869230740(21)196703, (01)04056869230740(21)196828, (01)04056869230740(21)196522, (01)04056869230740(21)196570, (01)04056869230740(21)196422, (01)04056869230740(21)196800, (01)04056869230740(21)196775, (01)04056869230740(21)196795, (01)04056869230740(21)196514, (01)04056869230740(21)196565, (01)04056869230740(21)196586, (01)04056869230740(21)196451, (01)04056869230740(21)196525, (01)04056869230740(21)196326, (01)04056869230740(21)196463, (01)04056869230740(21)196331, (01)04056869230740(21)196413, (01)04056869230740(21)196634, (01)04056869230740(21)196746, (01)04056869230740(21)196359, (01)04056869230740(21)196461, (01)04056869230740(21)196330, (01)04056869230740(21)196750, (01)04056869230740(21)196354, (01)04056869230740(21)196557, (01)04056869230740(21)196321, (01)04056869230740(21)196688, (01)04056869230740(21)196818, (01)04056869230740(21)196338, (01)04056869230740(21)196772, (01)04056869230740(21)196472, (01)04056869230740(21)196651, (01)04056869230740(21)196440, (01)04056869230740(21)196687, (01)04056869230740(21)196509, (01)04056869230740(21)196799, (01)04056869230740(21)196549, (01)04056869230740(21)196717, (01)04056869230740(21)196398, (01)04056869230740(21)196367, (01)04056869230740(21)196823, (01)04056869230740(21)196830, (01)04056869230740(21)196464, (01)04056869230740(21)196815. Serial Numbers: 196458, 196591, 196655, 196355, 196733, 196668, 196477, 196343, 196553, 196519, 196366, 196782, 196617, 196684, 196502, 196539, 196280, 196626, 196511, 196643, 196796, 196551, 196495, 196741, 196621, 196611, 196544, 196724, 196776, 196752, 196372, 196350, 196841, 196252, 196508, 196332, 196496, 196753, 196375, 196738, 196260, 196470, 196765, 196334, 196288, 196409, 196737, 196286, 196604, 196446, 196362, 196518, 196619, 196450, 196678, 196349, 196261, 196415, 196386, 196391, 196537, 196649, 196411, 196353, 196629, 196403, 196529, 196622, 196414, 196778, 196308, 196768, 196791, 196832, 196606, 196240, 196730, 196360, 196466, 196831, 196789, 196780, 196779, 196405, 196625, 196376, 196703, 196828, 196522, 196570, 196422, 196800, 196775, 196795, 196514, 196565, 196586, 196451, 196525, 196326, 196463, 196331, 196413, 196634, 196746, 196359, 196461, 196330, 196750, 196354, 196557, 196321, 196688, 196818, 196338, 196772, 196472, 196651, 196440, 196687, 196509, 196799, 196549, 196717, 196398, 196367, 196823, 196830, 196464, 196815.
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Siemens Medical Solutions USA, Inc
Reason for Recall:
There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing

Product Information

Full Description:

MAGNETOM Lumina (DE). Model Number: 11344916.

Product Codes/Lot Numbers:

Model Number: 11344916. UDI Numbers: (01)04056869230740(21)196458, (01)04056869230740(21)196591, (01)04056869230740(21)196655, (01)04056869230740(21)196355, (01)04056869230740(21)196733, (01)04056869230740(21)196668, (01)04056869230740(21)196477, (01)04056869230740(21)196343, (01)04056869230740(21)196553, (01)04056869230740(21)196519, (01)04056869230740(21)196366, (01)04056869230740(21)196782, (01)04056869230740(21)196617, (01)04056869230740(21)196684, (01)04056869230740(21)196502, (01)04056869230740(21)196539, (01)04056869230740(21)196280, (01)04056869230740(21)196626, (01)04056869230740(21)196511, (01)04056869230740(21)196643, (01)04056869230740(21)196796, (01)04056869230740(21)196551, (01)04056869230740(21)196495, (01)04056869230740(21)196741, (01)04056869230740(21)196621, (01)04056869230740(21)196611, (01)04056869230740(21)196544, (01)04056869230740(21)196724, (01)04056869230740(21)196776, (01)04056869230740(21)196752, (01)04056869230740(21)196372, (01)04056869230740(21)196350, (01)04056869230740(21)196841, (01)04056869230740(21)196252, (01)04056869230740(21)196508, (01)04056869230740(21)196332, (01)04056869230740(21)196496, (01)04056869230740(21)196753, (01)04056869230740(21)196375, (01)04056869230740(21)196738, (01)04056869230740(21)196260, (01)04056869230740(21)196470, (01)04056869230740(21)196765, (01)04056869230740(21)196334, (01)04056869230740(21)196288, (01)04056869230740(21)196409, (01)04056869230740(21)196737, (01)04056869230740(21)196286, (01)04056869230740(21)196604, (01)04056869230740(21)196446, (01)04056869230740(21)196362, (01)04056869230740(21)196518, (01)04056869230740(21)196619, (01)04056869230740(21)196450, (01)04056869230740(21)196678, (01)04056869230740(21)196349, (01)04056869230740(21)196261, (01)04056869230740(21)196415, (01)04056869230740(21)196386, (01)04056869230740(21)196391, (01)04056869230740(21)196537, (01)04056869230740(21)196649, (01)04056869230740(21)196411, (01)04056869230740(21)196353, (01)04056869230740(21)196629, (01)04056869230740(21)196403, (01)04056869230740(21)196529, (01)04056869230740(21)196622, (01)04056869230740(21)196414, (01)04056869230740(21)196778, (01)04056869230740(21)196308, (01)04056869230740(21)196768, (01)04056869230740(21)196791, (01)04056869230740(21)196832, (01)04056869230740(21)196606, (01)04056869230740(21)196240, (01)04056869230740(21)196730, (01)04056869230740(21)196360, (01)04056869230740(21)196466, (01)04056869230740(21)196831, (01)04056869230740(21)196789, (01)04056869230740(21)196780, (01)04056869230740(21)196779, (01)04056869230740(21)196405, (01)04056869230740(21)196625, (01)04056869230740(21)196376, (01)04056869230740(21)196703, (01)04056869230740(21)196828, (01)04056869230740(21)196522, (01)04056869230740(21)196570, (01)04056869230740(21)196422, (01)04056869230740(21)196800, (01)04056869230740(21)196775, (01)04056869230740(21)196795, (01)04056869230740(21)196514, (01)04056869230740(21)196565, (01)04056869230740(21)196586, (01)04056869230740(21)196451, (01)04056869230740(21)196525, (01)04056869230740(21)196326, (01)04056869230740(21)196463, (01)04056869230740(21)196331, (01)04056869230740(21)196413, (01)04056869230740(21)196634, (01)04056869230740(21)196746, (01)04056869230740(21)196359, (01)04056869230740(21)196461, (01)04056869230740(21)196330, (01)04056869230740(21)196750, (01)04056869230740(21)196354, (01)04056869230740(21)196557, (01)04056869230740(21)196321, (01)04056869230740(21)196688, (01)04056869230740(21)196818, (01)04056869230740(21)196338, (01)04056869230740(21)196772, (01)04056869230740(21)196472, (01)04056869230740(21)196651, (01)04056869230740(21)196440, (01)04056869230740(21)196687, (01)04056869230740(21)196509, (01)04056869230740(21)196799, (01)04056869230740(21)196549, (01)04056869230740(21)196717, (01)04056869230740(21)196398, (01)04056869230740(21)196367, (01)04056869230740(21)196823, (01)04056869230740(21)196830, (01)04056869230740(21)196464, (01)04056869230740(21)196815. Serial Numbers: 196458, 196591, 196655, 196355, 196733, 196668, 196477, 196343, 196553, 196519, 196366, 196782, 196617, 196684, 196502, 196539, 196280, 196626, 196511, 196643, 196796, 196551, 196495, 196741, 196621, 196611, 196544, 196724, 196776, 196752, 196372, 196350, 196841, 196252, 196508, 196332, 196496, 196753, 196375, 196738, 196260, 196470, 196765, 196334, 196288, 196409, 196737, 196286, 196604, 196446, 196362, 196518, 196619, 196450, 196678, 196349, 196261, 196415, 196386, 196391, 196537, 196649, 196411, 196353, 196629, 196403, 196529, 196622, 196414, 196778, 196308, 196768, 196791, 196832, 196606, 196240, 196730, 196360, 196466, 196831, 196789, 196780, 196779, 196405, 196625, 196376, 196703, 196828, 196522, 196570, 196422, 196800, 196775, 196795, 196514, 196565, 196586, 196451, 196525, 196326, 196463, 196331, 196413, 196634, 196746, 196359, 196461, 196330, 196750, 196354, 196557, 196321, 196688, 196818, 196338, 196772, 196472, 196651, 196440, 196687, 196509, 196799, 196549, 196717, 196398, 196367, 196823, 196830, 196464, 196815.

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2658-2025

Related Recalls

MAMMOMAT Inspiration;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →

MAMMOMAT Fusion;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →

MAMMOMAT Revelation;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →