MAGNETOM Cima.X (DE). Model Number: 11647158.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Model Number: 11647158. UDI Numbers: (01)04056869975221(21)213029, (01)04056869975221(21)213006, (01)04056869975221(21)213062, (01)04056869975221(21)213043, (01)04056869975221(21)213041, (01)04056869975221(21)213034, (01)04056869975221(21)213035, (01)04056869975221(21)213028, (01)04056869975221(21)213031, (01)04056869975221(21)213018, (01)04056869975221(21)213061, (01)04056869975221(21)213005, (01)04056869975221(21)213021, (01)04056869975221(21)213022, (01)04056869975221(21)213056, (01)04056869975221(21)213030, (01)04056869975221(21)213039, (01)04056869975221(21)213025, (01)04056869975221(21)213063, (01)04056869975221(21)213057, (01)04056869975221(21)213026, (01)04056869975221(21)213020. Serial Numbers: 213029, 213006, 213062, 213043, 213041, 213034, 213035, 213028, 213031, 213018, 213061, 213005, 213021, 213022, 213056, 213030, 213039, 213025, 213063, 213057, 213026, 213020.
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Siemens Medical Solutions USA, Inc
Reason for Recall:
There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing

Product Information

Full Description:

MAGNETOM Cima.X (DE). Model Number: 11647158.

Product Codes/Lot Numbers:

Model Number: 11647158. UDI Numbers: (01)04056869975221(21)213029, (01)04056869975221(21)213006, (01)04056869975221(21)213062, (01)04056869975221(21)213043, (01)04056869975221(21)213041, (01)04056869975221(21)213034, (01)04056869975221(21)213035, (01)04056869975221(21)213028, (01)04056869975221(21)213031, (01)04056869975221(21)213018, (01)04056869975221(21)213061, (01)04056869975221(21)213005, (01)04056869975221(21)213021, (01)04056869975221(21)213022, (01)04056869975221(21)213056, (01)04056869975221(21)213030, (01)04056869975221(21)213039, (01)04056869975221(21)213025, (01)04056869975221(21)213063, (01)04056869975221(21)213057, (01)04056869975221(21)213026, (01)04056869975221(21)213020. Serial Numbers: 213029, 213006, 213062, 213043, 213041, 213034, 213035, 213028, 213031, 213018, 213061, 213005, 213021, 213022, 213056, 213030, 213039, 213025, 213063, 213057, 213026, 213020.

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2656-2025

Related Recalls

During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

Mar 9, 2026 Other Medical Devices View Details →
Class I - Dangerous

During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

Mar 9, 2026 Other Medical Devices View Details →

ARTIS Pheno VE30A and VE40A, Model 10849000

Siemens Medical Solutions USA

Class I - Dangerous

During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.

Mar 12, 2026 Other Medical Devices View Details →