MAMMOMAT Revelation, model no. 11343300 - Product Usage: is intended to be used for mammography exams, screening, diagnostics, biopsies and dual energy procedures under the supervision of medical professionals.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Serial Numbers (distributed in the US): 1026 1057 1348 1426 1027 1274 1292 1360 1324 1728 1372 1744 1036 1038 1620 1235 1751 1423 1379 1425 1342 1740 1445 1650 1058 1409 1277 1025 1253 1225 1749 1747 1422 1275 1228 1449 1707 1767 1387 1391 1206 1217 1250 1082 1357 1354 1256 1031 1339 1034 1219 1437 1289 1359 1045 1429 1408 1717 1051 ***Updated 8/18/2020*** 1775 1784 1785 1795 1797
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Siemens Medical Solutions USA, Inc
Reason for Recall:
If an examination is interrupted when the InSpect Projection View (PV) is active and the vacuum biopsy system is being used, the tube arm's manual movement range is decreased from +/-15 deg. to +/- 6 deg. This limitation may lead to difficulties in removing the vacuum biopsy system.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

MAMMOMAT Revelation, model no. 11343300 - Product Usage: is intended to be used for mammography exams, screening, diagnostics, biopsies and dual energy procedures under the supervision of medical professionals.

Product Codes/Lot Numbers:

Serial Numbers (distributed in the US): 1026 1057 1348 1426 1027 1274 1292 1360 1324 1728 1372 1744 1036 1038 1620 1235 1751 1423 1379 1425 1342 1740 1445 1650 1058 1409 1277 1025 1253 1225 1749 1747 1422 1275 1228 1449 1707 1767 1387 1391 1206 1217 1250 1082 1357 1354 1256 1031 1339 1034 1219 1437 1289 1359 1045 1429 1408 1717 1051 ***Updated 8/18/2020*** 1775 1784 1785 1795 1797

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2388-2020

Related Recalls

MAMMOMAT Inspiration;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →

MAMMOMAT Fusion;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →

MAMMOMAT Revelation;

Siemens Medical Solutions USA

Class I - Dangerous

There were instances where the operator table was sold together with a bus-installation kit. The operator table is not intended and not released for bus installations as it was designed for stationary operation only.

Oct 24, 2025 Other Medical Devices Nationwide View Details →