VACUETTE¿ TUBE 8 ml CAT Serum Separator Clot Activator 16x100 red cap-yellow ring, non-ridged

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Item Number: 455071P; UDI Case label: 39120017573068; UDI Rack label: 29120017573061; Lot Number: B24013MV
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Greiner Bio-One North America, Inc.
Reason for Recall:
The firm received reports that some blood collection tubes have experienced issues with clotting and poor separation due to missing additive. The failure of the device would likely require sample recollection which could result in a delay of treatment.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
ongoing

Product Information

Full Description:

VACUETTE¿ TUBE 8 ml CAT Serum Separator Clot Activator 16x100 red cap-yellow ring, non-ridged

Product Codes/Lot Numbers:

Item Number: 455071P; UDI Case label: 39120017573068; UDI Rack label: 29120017573061; Lot Number: B24013MV

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2375-2024

Related Recalls

Some of the Vacuette¿ CAT Serum Separator Clot Activator tubes were manufactured without gel separator, which could yield erroneous assay results and require the patient to return to the lab for recollection or repeat testing. This may result in delayed diagnosis, cause a delay in clinical decision-making or treatment and in some rare cases, yield incorrect results from less stable parameters.

Aug 19, 2025 Infusion Pumps Nationwide View Details →

Tubes have missing additive/anticoagulant resulting in clotting in most cases. A completely clotted sample would lead to no results being reported, which could lead to a delay in treatment or diagnosis. An erroneous glucose or lactose result from a partially clotted sample could lead to inappropriate treatment.

Dec 12, 2023 Other Medical Devices Nationwide View Details →