Zimmer¿ M/L Taper Hip Prosthesis Plasma Sprayed, Size 4 Standard Offset; 00-7711-004-10

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    62107667 62410983 62410984 62445410 62449677 62450635 62469393 62478848 62478852 62478855 62503181 62547038 62554172 62559999 62560152 62577929 62630007 62636746 62652981 62659334 62667678 62753395 62770876 62777941 62791158 62806022 62897465
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Zimmer Biomet, Inc.
Reason for Recall:
M/L Taper Hip Prosthesis and M/L Taper Hip Prosthesis with Kinectiv Technology manufactured prior to October 2015 are being recalled due to the potential for black residue to be observed within the polyethylene bag containing the implant. The black residue is a combination of the titanium plasma spray used to create the porous surface of the implant and polyethylene bag containing the implant. The recalling firm states the residue is biocompatible. Risks include delay of surgery while locating a replacement device, and surgical intervention due to wear caused by debris.
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Zimmer¿ M/L Taper Hip Prosthesis Plasma Sprayed, Size 4 Standard Offset; 00-7711-004-10

Product Codes/Lot Numbers:

62107667 62410983 62410984 62445410 62449677 62450635 62469393 62478848 62478852 62478855 62503181 62547038 62554172 62559999 62560152 62577929 62630007 62636746 62652981 62659334 62667678 62753395 62770876 62777941 62791158 62806022 62897465

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2362-2018

Related Recalls

Zimmer Biomet is conducting a medical device correction to update the Instructions for Use (IFU) and the Surgical Techniques for the Polaris Spinal System Translation Screw and Cypher MIS Screw System. Users should be aware that changes were made to the contraindications section indicating that the Translation Screws should not be used with a direct current stimulation, as a high probability of construct failure exists when using Translation Screws containing CoCr with direct current simulation system.

Nov 17, 2020 Other Medical Devices Nationwide View Details →