Roche Elecsys Anti-CCP Immunoassay Catalog # 07251670190
Class I - DangerousWhat Should You Do?
- Check if you have this product: Lot # 376648 Exp : 08/31/2019 Lot # 388800 Exp : 09/30/2019 Anti-CCP assay: Anti-CCP Elecsys E2G 100 The affected lots of Anti-CCP have been distributed 02/28/2019 through 07/01/2019. ***Updated 7/17/20*** Current (in-date) and future lots of both Catalog numbers are impacted. In-date lots: 461913, exp 7/31/2020 467132, exp 9/30/2020
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- Roche Diagnostics Operations, Inc.
- Reason for Recall:
- Performance issues with certain lots of the Elecsys Anti-CCP assay on the cobas e 411 analyzer; MODULAR ANALYTICS E 170 module; and cobas e 601, 602, and 801 modules with plasma samples.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
Roche Elecsys Anti-CCP Immunoassay Catalog # 07251670190
Product Codes/Lot Numbers:
Lot # 376648 Exp : 08/31/2019 Lot # 388800 Exp : 09/30/2019 Anti-CCP assay: Anti-CCP Elecsys E2G 100 The affected lots of Anti-CCP have been distributed 02/28/2019 through 07/01/2019. ***Updated 7/17/20*** Current (in-date) and future lots of both Catalog numbers are impacted. In-date lots: 461913, exp 7/31/2020 467132, exp 9/30/2020
Distribution:
Nationwide distribution
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2361-2019
Related Recalls
cobas HCYS, Homocysteine Enzymatic Assay, Material Number REF 06542921190, for use on cobas c 701/702, in vitro test for total L-homocysteine
Roche Diagnostics Operations
Abnormal calibration signals and control recovery issues on the Homocysteine Enzymatic (HCYS) Assay can produce erroneous patient results (positive or negative bias)
Creatine Kinase (CK) used on cobas c 311/501/502 and COBAS INTEGRA 400 plus-In vitro test for the quantitative determination of creatine kinase (CK) in human serum and plasma. Catalog Number: 07190794190
Roche Diagnostics Operations
Creatine Kinase (CK) Assay Abnormal calibrations on the cobas¿ c 311/501/502 and COBAS INTEGRA 400 plus Analyzers may lead to erroneous results and misdiagnosis.
Tina-quant D-Dimer Test System, Fibrinogen/Fibrin Degradation Products Assay, Material Numbers 03001245322 - (cobas c 311, 501 and 502; INTEGRA 400 plus), 08105618190 - (cobas c 303 and 503)
Roche Diagnostics Operations
Elevated results were detected with Li-heparin plasma samples when compared to citrated plasma samples.