Zimmer¿ Air Dermatome II Handpiece w/o Hose, item number 00-8851-001-01. The Zimmer Air Dermatome II handpiece and width plates are packaged inside of a padded-foam corrugate box. An operating manual is packed with the handpiece between the top foam pad and box lid. A product label is applied to the lid of the box. The width plates, when sold individually, are placed in a labeled poly zipper bag, which is then placed into a corrugated shipper carton or padded envelope. The Zimmer Air Dermatome II is a skin grafting instrument that is intended to provide variable graft thickness and width capabilities.

Class I - Dangerous

What Should You Do?

  1. Check if you have this product:
    Lot # 61987607, Serial # 500041  500060 Lot # 61989397, Serial # 500061  500080 Lot # 62007988, Serial # 500111  500130 Lot # 62008620, Serial # 500131  500150 Lot # 62244213, Serial # 500311  500330 Lot # 62267555, Serial # 500392  500411 Lot # 62289845, Serial # 500432  500451 Lot # 62309684, Serial # 500492  500511 Lot # 62374706, Serial # 500572  500591 Lot # 62393940, Serial # 500612  500631 Lot # 62415890, Serial # 500672  500691
  2. Do not eat it: Even if it looks and smells fine, do not consume this product.
  3. Throw it away or return it: You can return the product to the store for a full refund.
  4. Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
  5. Report problems: Report any issues to the FDA's Safety Reporting Portal.

⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.

Recall Details

Company:
Zimmer Surgical Inc
Reason for Recall:
The surface coating applied to the device is blistering, peeling and discoloring after usage over time
Classification:
Class I - Dangerous

Dangerous or defective products that predictably could cause serious health problems or death.

Status:
terminated

Product Information

Full Description:

Zimmer¿ Air Dermatome II Handpiece w/o Hose, item number 00-8851-001-01. The Zimmer Air Dermatome II handpiece and width plates are packaged inside of a padded-foam corrugate box. An operating manual is packed with the handpiece between the top foam pad and box lid. A product label is applied to the lid of the box. The width plates, when sold individually, are placed in a labeled poly zipper bag, which is then placed into a corrugated shipper carton or padded envelope. The Zimmer Air Dermatome II is a skin grafting instrument that is intended to provide variable graft thickness and width capabilities.

Product Codes/Lot Numbers:

Lot # 61987607, Serial # 500041  500060 Lot # 61989397, Serial # 500061  500080 Lot # 62007988, Serial # 500111  500130 Lot # 62008620, Serial # 500131  500150 Lot # 62244213, Serial # 500311  500330 Lot # 62267555, Serial # 500392  500411 Lot # 62289845, Serial # 500432  500451 Lot # 62309684, Serial # 500492  500511 Lot # 62374706, Serial # 500572  500591 Lot # 62393940, Serial # 500612  500631 Lot # 62415890, Serial # 500672  500691

Official Source

Always verify recall information with the official FDA source:

View on FDA.gov

FDA Recall Number: Z-2335-2016

Related Recalls

Skin grafts thin and non-uniform when using the affected blades. The issue would be identified at the time of use and may result in the need for additional harvests to adequately cover the area

Sep 5, 2023 Surgical Instruments Nationwide View Details →

When inflating/deflating a single bladder, both bladders could potentially inflate/deflate due to a leak between the bladders.