DeVilbiss Vacu-Aide QSU Suction Unit (Disposable Suction Container/Filter), 800 ML DISP Container, Unassembled, 800 ML DISP Container w/6' patient tubing, and 800 ML DISP Container w/6' patient tubing, assembled. DeVilbiss Vacu-Aide QSU Suction Unit (Disposable Suction Container/Filter) is used to remove fluids from the airway or respiratory support system and infectious materials from wounds. It is available for use by consumers by physician order.
Class I - DangerousWhat Should You Do?
- Check if you have this product: Part Number 7305D-634 with model numbers 7305D-632, 7305D-633, and 7305D-633-25
- Do not eat it: Even if it looks and smells fine, do not consume this product.
- Throw it away or return it: You can return the product to the store for a full refund.
- Seek medical attention if needed: If you've consumed this product and feel unwell, contact your doctor immediately.
- Report problems: Report any issues to the FDA's Safety Reporting Portal.
⚠️ Emergency: If you experience severe symptoms after consuming this product, call 911 or Poison Control at 1-800-222-1222.
Recall Details
- Company:
- DeVilbiss Healthcare LLC
- Reason for Recall:
- End users of the DeVilbiss Disposable Suction Container/Filter had exposed the bacterial filter cartridge to fluid, thereby occluding the filter and rendering it unusable.
- Classification:
- Class I - Dangerous
Dangerous or defective products that predictably could cause serious health problems or death.
- Status:
- terminated
Product Information
Full Description:
DeVilbiss Vacu-Aide QSU Suction Unit (Disposable Suction Container/Filter), 800 ML DISP Container, Unassembled, 800 ML DISP Container w/6' patient tubing, and 800 ML DISP Container w/6' patient tubing, assembled. DeVilbiss Vacu-Aide QSU Suction Unit (Disposable Suction Container/Filter) is used to remove fluids from the airway or respiratory support system and infectious materials from wounds. It is available for use by consumers by physician order.
Product Codes/Lot Numbers:
Part Number 7305D-634 with model numbers 7305D-632, 7305D-633, and 7305D-633-25
Official Source
Always verify recall information with the official FDA source:
View on FDA.govFDA Recall Number: Z-2319-2013
Related Recalls
DEVILBISS HEALTHCARE 1025 SERIES OXYGEN CONCENTRATOR, Model Numbers 1025DS, 1025UK, 1025KS, and 1025KS-AR
DeVilbiss Healthcare
The instruction manual is being replaced with an updated version that is in alignment with labeling requirements specified in the IEC-60101-1 standard.
DeVilbiss, 525 5-liter Oxygen Concentrator Models 525DS, 525DS-Q
DeVilbiss Healthcare
The firm has received complaints of the device becoming hot. The firm has updated the user manual to include warnings that applied parts in contact with the patient may in some situations exceed 41 degrees Celsius (105.8 degrees Fahrenheit), clarification on expected service life, and the need for maintenance to certain components.
125 series iGO2 Portable Oxygen Concentrator-indicated for the administration of supplemental oxygen. Models: 125D, 125D-XB
DeVilbiss Healthcare
An unapproved adhesive used to manufacture the accumulator tank sub assembly (a part of the patient gas pathway)